We have located links that may give you full text access.
Comparative Study
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Comparison of Pneumatic Retinopexy and Scleral Buckle for Primary Rhegmatogenous Retinal Detachment Repair.
Ophthalmic Surgery, Lasers & Imaging Retina 2017 November 2
BACKGROUND AND OBJECTIVE: To compare pneumatic retinopexy (PR) and scleral buckle for the repair of primary rhegmatogenous retinal detachment.
PATIENTS AND METHODS: Retrospective analysis of 90 patients undergoing surgery for primary rhegmatogenous retinal detachment, with 46 patients undergoing PR compared with 44 patients undergoing scleral buckle procedure (SBP).
RESULTS: Both groups had similar baseline characteristics. Single surgery reattachment rate was 95.5% with SBP and 67% with PR (P = .00057). Final reattachment rate was 100% with SBP and 97.8% with PR. A final visual acuity (VA) of 20/40 or better occurred in 89% of patients with SBP and 72% of patients with PR (P = .04). PR and SBP had a similar mean VA if the primary procedures were successful, whereas those patients with unsuccessful PR had lower mean final acuities.
CONCLUSIONS: This study demonstrates that SBP has a significantly higher rate of single surgery reattachment than PR, along with improved final VA. Initial success of PR may be an important predictor of final visual outcome. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:887-893.].
PATIENTS AND METHODS: Retrospective analysis of 90 patients undergoing surgery for primary rhegmatogenous retinal detachment, with 46 patients undergoing PR compared with 44 patients undergoing scleral buckle procedure (SBP).
RESULTS: Both groups had similar baseline characteristics. Single surgery reattachment rate was 95.5% with SBP and 67% with PR (P = .00057). Final reattachment rate was 100% with SBP and 97.8% with PR. A final visual acuity (VA) of 20/40 or better occurred in 89% of patients with SBP and 72% of patients with PR (P = .04). PR and SBP had a similar mean VA if the primary procedures were successful, whereas those patients with unsuccessful PR had lower mean final acuities.
CONCLUSIONS: This study demonstrates that SBP has a significantly higher rate of single surgery reattachment than PR, along with improved final VA. Initial success of PR may be an important predictor of final visual outcome. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:887-893.].
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app