We have located links that may give you full text access.
JOURNAL ARTICLE
META-ANALYSIS
REVIEW
SYSTEMATIC REVIEW
Diagnostic Accuracy of Monofilament Tests for Detecting Diabetic Peripheral Neuropathy: A Systematic Review and Meta-Analysis.
Objective: To systematically evaluate the diagnostic accuracy of monofilament tests for detecting diabetic peripheral neuropathy.
Methods: We searched EMBASE (OvidSP), MEDLINE (OvidSP), the Cochrane Library, and Web of Science to identify diagnostic accuracy trials of monofilament tests for detecting diabetic peripheral neuropathy. We used a hierarchical summary receiver operating characteristics (HSROC) model to conduct the meta-analysis of diagnostic accuracy of monofilament tests for detecting diabetic peripheral neuropathy.
Results: A total of 19 comparative trials met the inclusion criteria and were part of the qualitative synthesis. Eight trials using nerve conduction studies as the reference standard were selected for the meta-analysis. The pooled sensitivity and specificity of monofilament tests for detecting diabetic peripheral neuropathy were 0.53 (95% confidence interval (CI) 0.32 to 0.74) and 0.88 (95% CI 0.78 to 0.94), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 4.56 (95% CI 2.93 to 7.10) and 0.53 (95% CI 0.35 to 0.81), respectively.
Conclusions: Our review indicated that monofilament tests had limited sensitivity for screening diabetic peripheral neuropathy. The clinical use of the monofilament test in the evaluation of diabetic peripheral neuropathy cannot be encouraged based on currently available evidence.
Methods: We searched EMBASE (OvidSP), MEDLINE (OvidSP), the Cochrane Library, and Web of Science to identify diagnostic accuracy trials of monofilament tests for detecting diabetic peripheral neuropathy. We used a hierarchical summary receiver operating characteristics (HSROC) model to conduct the meta-analysis of diagnostic accuracy of monofilament tests for detecting diabetic peripheral neuropathy.
Results: A total of 19 comparative trials met the inclusion criteria and were part of the qualitative synthesis. Eight trials using nerve conduction studies as the reference standard were selected for the meta-analysis. The pooled sensitivity and specificity of monofilament tests for detecting diabetic peripheral neuropathy were 0.53 (95% confidence interval (CI) 0.32 to 0.74) and 0.88 (95% CI 0.78 to 0.94), respectively. The pooled positive likelihood ratio and negative likelihood ratio were 4.56 (95% CI 2.93 to 7.10) and 0.53 (95% CI 0.35 to 0.81), respectively.
Conclusions: Our review indicated that monofilament tests had limited sensitivity for screening diabetic peripheral neuropathy. The clinical use of the monofilament test in the evaluation of diabetic peripheral neuropathy cannot be encouraged based on currently available evidence.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app