Plethysmography variability index for prediction of fluid responsiveness during graded haemorrhage and transfusion in sevoflurane-anaesthetized mechanically ventilated dogs.
Veterinary Anaesthesia and Analgesia 2017 November
OBJECTIVE: To examine the accuracy of plethysmography variability index (PVI) as a noninvasive indicator of fluid responsiveness in hypovolaemic dogs.
STUDY DESIGN: Prospective experimental study.
ANIMALS: Six adult healthy sevoflurane-anaesthetized Beagle dogs.
METHODS: Dogs were anaesthetized with 1.3-fold their individual minimum alveolar concentration of sevoflurane. The lungs were mechanically ventilated after neuromuscular blockade with vecuronium bromide. Cardiopulmonary variables including mean arterial blood pressure (MAP), central venous pressure (CVP), transpulmonary thermodilution cardiac output (TPTDCO), stroke volume (SV), perfusion index (PI), pulse pressure variation (PPV), stroke volume variation (SVV) and PVI were determined during six stages of graded venous blood withdrawal (5 mL kg-1 increments) and six stages of graded blood infusion (5 mL kg-1 increments). The cardiopulmonary variables were analysed using paired t test or Wilcoxon signed rank test. Correlations between PPV and SVV or PVI were analysed by linear regression. The accuracy of PPV, SVV and PVI for predicting fluid responsiveness was examined by using receiver operating characteristic curve analysis. A value of p < 0.05 was considered statistically significant.
RESULTS: Blood withdrawal resulted in significant increases in PPV and PVI and decreases in MAP, CVP, TPTDCO, SV and PI. Blood infusion resulted in significant increases in MAP, CVP, TPTDCO, SV and PI and decreases in PPV and PVI. PPV and PVI showed a relevant correlation (p < 0.001, r2 = 0.62) and threshold values of PPV ≥ 16% (sensitivity 71%, specificity 82%) and PVI ≥ 12% (sensitivity 78%, specificity 72%) for identifying fluid responsiveness. SVV did not change.
CONCLUSIONS AND CLINICAL RELEVANCE: Noninvasive measurement of PVI predicted fluid responsiveness with moderate accuracy equal to PPV in sevoflurane-anaesthetized mechanically ventilated dogs. Provisional threshold values for identification of fluid responsiveness were PPV ≥ 16% and PVI ≥ 12%. Clinical trials are needed to confirm these threshold values in dogs.
STUDY DESIGN: Prospective experimental study.
ANIMALS: Six adult healthy sevoflurane-anaesthetized Beagle dogs.
METHODS: Dogs were anaesthetized with 1.3-fold their individual minimum alveolar concentration of sevoflurane. The lungs were mechanically ventilated after neuromuscular blockade with vecuronium bromide. Cardiopulmonary variables including mean arterial blood pressure (MAP), central venous pressure (CVP), transpulmonary thermodilution cardiac output (TPTDCO), stroke volume (SV), perfusion index (PI), pulse pressure variation (PPV), stroke volume variation (SVV) and PVI were determined during six stages of graded venous blood withdrawal (5 mL kg-1 increments) and six stages of graded blood infusion (5 mL kg-1 increments). The cardiopulmonary variables were analysed using paired t test or Wilcoxon signed rank test. Correlations between PPV and SVV or PVI were analysed by linear regression. The accuracy of PPV, SVV and PVI for predicting fluid responsiveness was examined by using receiver operating characteristic curve analysis. A value of p < 0.05 was considered statistically significant.
RESULTS: Blood withdrawal resulted in significant increases in PPV and PVI and decreases in MAP, CVP, TPTDCO, SV and PI. Blood infusion resulted in significant increases in MAP, CVP, TPTDCO, SV and PI and decreases in PPV and PVI. PPV and PVI showed a relevant correlation (p < 0.001, r2 = 0.62) and threshold values of PPV ≥ 16% (sensitivity 71%, specificity 82%) and PVI ≥ 12% (sensitivity 78%, specificity 72%) for identifying fluid responsiveness. SVV did not change.
CONCLUSIONS AND CLINICAL RELEVANCE: Noninvasive measurement of PVI predicted fluid responsiveness with moderate accuracy equal to PPV in sevoflurane-anaesthetized mechanically ventilated dogs. Provisional threshold values for identification of fluid responsiveness were PPV ≥ 16% and PVI ≥ 12%. Clinical trials are needed to confirm these threshold values in dogs.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app