We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Early experience and favorable clinical outcomes of everolimus-eluting bioresorbable scaffolds for coronary artery disease in Korea.
Korean Journal of Internal Medicine 2018 September
BACKGROUND/AIMS: Compared with metallic drug-eluting stents (DES), bioresorbable vascular scaffolds (BVS) may further improve long-term outcomes of percutaneous coronary intervention (PCI) in patients with coronary artery disease. We report our early experience with BVS in Korea.
METHODS: We evaluated 105 consecutive patients with BVS implanted at Asan Medical Center, Korea between October 21, 2015 and June 3, 2016. Angiographic results, and in-hospital and 6-month clinical outcomes were assessed.
RESULTS: A total of 134 BVS were implanted to treat 115 lesions. The mean age was 62 ± 10.5 years; 85 patients (81%) were males, 26 patients (25%) were presented with acute coronary syndrome. Among 115 lesions treated with BVS, 76 (66.1%) were B2/C type, 27 (23.5%) were bifurcation lesions, and four (3.5%) were chronic total occlusion. Pre-dilation and post-dilation using high-pressure non-compliant balloon was performed in 104 lesions (90.4%) and 113 lesions (98.2%), respectively. During the procedure, intravascular imaging was used for all patients (100%; intravascular ultrasound 89 and optical coherence tomography 40 patients). Device success rate was 100%. In-segment and in-scaffold acute again were 1.1 ± 0.6 and 1.3 ± 0.5 mm, respectively. Periprocedural myocardial infraction occurred in four patients (3.8%). No deaths, stent thrombosis, or urgent revascularizations occurred either during hospitalization or the follow-up period.
CONCLUSION: In this single-center experience, implantation of BVS with intravascular imaging support was feasible and early clinical outcomes were excellent. Evaluation of long-term efficacy and safety of BVS and its feasibility in clinical use for a broader range of lesions is warranted.
METHODS: We evaluated 105 consecutive patients with BVS implanted at Asan Medical Center, Korea between October 21, 2015 and June 3, 2016. Angiographic results, and in-hospital and 6-month clinical outcomes were assessed.
RESULTS: A total of 134 BVS were implanted to treat 115 lesions. The mean age was 62 ± 10.5 years; 85 patients (81%) were males, 26 patients (25%) were presented with acute coronary syndrome. Among 115 lesions treated with BVS, 76 (66.1%) were B2/C type, 27 (23.5%) were bifurcation lesions, and four (3.5%) were chronic total occlusion. Pre-dilation and post-dilation using high-pressure non-compliant balloon was performed in 104 lesions (90.4%) and 113 lesions (98.2%), respectively. During the procedure, intravascular imaging was used for all patients (100%; intravascular ultrasound 89 and optical coherence tomography 40 patients). Device success rate was 100%. In-segment and in-scaffold acute again were 1.1 ± 0.6 and 1.3 ± 0.5 mm, respectively. Periprocedural myocardial infraction occurred in four patients (3.8%). No deaths, stent thrombosis, or urgent revascularizations occurred either during hospitalization or the follow-up period.
CONCLUSION: In this single-center experience, implantation of BVS with intravascular imaging support was feasible and early clinical outcomes were excellent. Evaluation of long-term efficacy and safety of BVS and its feasibility in clinical use for a broader range of lesions is warranted.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app