Assessing the viscoelastic properties of upper trapezius muscle: Intra- and inter-tester reliability and the effect of shoulder elevation.
Journal of Electromyography and Kinesiology 2018 December
BACKGROUND: Increasing stiffness in the upper trapezius muscle may contribute to imbalance of scapular motion, and result in shoulder and neck discomfort during shoulder flexion. Therefore, it is essential to quantify upper trapezius stiffness in various shoulder positions in order to aid in the prevention of these disorders and to optimize rehabilitation.
OBJECTIVES: The objectives of the present study were to examine the intra and inter-tester reliability of MyotonPRO device in measuring upper trapezius stiffness and its ability to determine changes in stiffness during shoulder flexion.
METHODS: Twenty healthy male subjects (mean age: 28.3±4.8 years) were studied. The stiffness of upper trapezius was quantified using the MyotonPRO device.
RESULTS: The results revealed excellent intra and inter-tester reliability for measuring upper trapezius stiffness with the shoulder in a neutral position, and also found a 14.2% increase in stiffness upon shoulder flexion between 0° and 60° of flexion. Minimal detectable change (MDC) was 26.3 N/m.
CONCLUSIONS: Our findings indicate that MyotonPRO device is a feasible tool to quantify upper trapezius stiffness as well as changes in muscle stiffness. Thus, it is important to assess the changes in upper trapezius muscle stiffness due to pathology or treatments for future studies.
OBJECTIVES: The objectives of the present study were to examine the intra and inter-tester reliability of MyotonPRO device in measuring upper trapezius stiffness and its ability to determine changes in stiffness during shoulder flexion.
METHODS: Twenty healthy male subjects (mean age: 28.3±4.8 years) were studied. The stiffness of upper trapezius was quantified using the MyotonPRO device.
RESULTS: The results revealed excellent intra and inter-tester reliability for measuring upper trapezius stiffness with the shoulder in a neutral position, and also found a 14.2% increase in stiffness upon shoulder flexion between 0° and 60° of flexion. Minimal detectable change (MDC) was 26.3 N/m.
CONCLUSIONS: Our findings indicate that MyotonPRO device is a feasible tool to quantify upper trapezius stiffness as well as changes in muscle stiffness. Thus, it is important to assess the changes in upper trapezius muscle stiffness due to pathology or treatments for future studies.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app