Add like
Add dislike
Add to saved papers

Effect of temperature on copper, iron and lead leaching from e-waste using citrate solutions.

Waste Management 2018 January
E-waste is a potential source of large quantities of metals. The ability of citrate solutions to recover base metals from these materials has been demonstrated. In the present study, the effect of the temperature on base metal leaching capacity by the citrate solutions is determined. The material employed consisted of a mechanically prepared, gravity concentrated e-waste, with a metallic content greater than 90%. The leaching conditions were selected based on previous research performed by the authors (0.5 M sodium citrate, pH 4.5 and 20 g per liter e-waste concentrate). Leaching tests were performed at temperatures between 0° and 70 °C. The initial leaching rates for the three metals increased with temperature. However, these tapered off with time for temperatures above 30 °C, which can be associated to citrate destruction.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app