JOURNAL ARTICLE
REVIEW
Add like
Add dislike
Add to saved papers

An overview of cochlear implant electrode array designs.

Hearing Research 2017 December
Cochlear implant electrode arrays are designed with specific characteristics that allow for the preservation of intra-cochlear structures during the insertion process, as well as during explantation. Straight lateral wall (LW) electrode arrays and pre-curved modiolar hugging (MH) electrode arrays are the two types that are commercially available. Although there is a third type of electrode array called the mid-scala (MS), which is positioned in the middle of the scala tympani (ST), and is usually considered as an MH type of electrode. Different lengths of straight LW electrode arrays are currently available which allow for insertion across a range of different sized cochleae; however, due to manufacturing limitations, pre-curved MH electrodes are generally only available to cover the basal turn of the cochlea, while the spiral ganglion cells are distributed in the Rosenthal's canal that extends into 1.75 turns of the cochlea. Both straight LW and pre-curved MH electrodes can cause a certain degree of intra-cochlear trauma, but pre-curved MH electrodes tend to deviate into the scala vestibuli from the scala tympani more often than the straight LW electrodes, resulting in damage to the osseous spiral lamina/spiral ligament which could initiate new bone formation and eventually affect the cochlear implant users' hearing performance. Structural damage to the cochlea could also affect the vestibular function. With pre-curved MH electrodes, higher degrees of trauma are related to the fixed curling geometry of the electrode in relation to the variable coiling pattern of individual cochleae, the orientation of the electrode contacts in relation to the modiolus wall, and how effectively the stylet was handled by the surgeon during the procedure. Wire management, metal density, and the shore hardness of the silicone elastomer all contribute to the stiffness/flexibility of the electrode. It is important to acknowledge the impact of bringing the stimulating contacts closer to the modiolus wall with an MH electrode type in terms of the resultant damage to intra-cochlear structures. The presence of malformed cochleae should be identified and appropriate electrodes should be chosen for each specific cochlea, irrespective of the cochlear implant brand. In order to utilize drug therapy, the cochlea should be free from any trauma.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app