We have located links that may give you full text access.
Relationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle.
Magnetic Resonance in Medicine 2018 July
PURPOSE: To establish a series of relationships defining how muscle microstructure and diffusion tensor imaging (DTI) are related.
METHODS: The relationship among key microstructural features of skeletal muscle (fiber size, fibrosis, edema, and permeability) and the diffusion tensor were systematically simulated over physiologically relevant dimensions individually, and in combination, using a numerical simulation application. Stepwise multiple regression was used to identify which microstructural features of muscle significantly predict the diffusion tensor using single-echo and multi-echo DTI pulse sequences. Simulations were also performed in models with histology-informed geometry to investigate the relationship between fiber size and the diffusion tensor in models with real muscle geometry.
RESULTS: Fiber size is the strongest predictor of λ2, λ3, mean diffusivity, and fractional anisotropy in skeletal muscle, accounting for approximately 40% of the variance in the diffusion model when calculated with single-echo DTI. This increased to approximately 70% when diffusion measures were calculated from the short T2 component of the multi-echo DTI sequence. This nonlinear relationship begins to plateau in fibers with greater than 60-μm diameter.
CONCLUSIONS: As the normal fiber size of a human muscle fiber is 40 to 60 μm, this suggests that DTI is a sensitive tool to monitor muscle atrophy, but may be limited in measurements of muscle with larger fibers. Magn Reson Med 80:317-329, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
METHODS: The relationship among key microstructural features of skeletal muscle (fiber size, fibrosis, edema, and permeability) and the diffusion tensor were systematically simulated over physiologically relevant dimensions individually, and in combination, using a numerical simulation application. Stepwise multiple regression was used to identify which microstructural features of muscle significantly predict the diffusion tensor using single-echo and multi-echo DTI pulse sequences. Simulations were also performed in models with histology-informed geometry to investigate the relationship between fiber size and the diffusion tensor in models with real muscle geometry.
RESULTS: Fiber size is the strongest predictor of λ2, λ3, mean diffusivity, and fractional anisotropy in skeletal muscle, accounting for approximately 40% of the variance in the diffusion model when calculated with single-echo DTI. This increased to approximately 70% when diffusion measures were calculated from the short T2 component of the multi-echo DTI sequence. This nonlinear relationship begins to plateau in fibers with greater than 60-μm diameter.
CONCLUSIONS: As the normal fiber size of a human muscle fiber is 40 to 60 μm, this suggests that DTI is a sensitive tool to monitor muscle atrophy, but may be limited in measurements of muscle with larger fibers. Magn Reson Med 80:317-329, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app