Central arteriovenous anastomosis to treat resistant hypertension.
Current Opinion in Nephrology and Hypertension 2018 January
PURPOSE OF REVIEW: Novel, interventional treatments have emerged in the last decade for the treatment of resistant hypertension. This review focuses on a unique device that creates a fixed calibre, central iliac arteriovenous anastomosis that is significantly different in haemodynamic and safety profile from traditional haemodialysis fistulae. The background, physiology, and clinical data to date will be presented.
RECENT FINDINGS: The single, randomized, controlled clinical trial using the ROX coupler in patients with resistant hypertension demonstrated substantial reductions in both office and ambulatory blood pressure to 12-month postimplantation. There was a common, but manageable, adverse effect of upstream iliac venous stenosis causing ipsilateral lower limb oedema. There were no renal safety concerns. The mechanism of action is proposed to be mechanical by provision of a low-pressure parallel circuit attached to the high-pressure arterial system though detailed physiological evaluation is currently lacking.
SUMMARY: Preliminary data using the ROX coupler to form a central arteriovenous anastomosis are very encouraging. Concerns regarding the lack of sham control are to some extent mitigated by immediate on table blood pressure reduction with opening of the coupler and will be further addressed in the ongoing pivotal, sham-controlled ROX CONTROL Hypertension2 study which should provide further robust information regarding efficacy and safety.
RECENT FINDINGS: The single, randomized, controlled clinical trial using the ROX coupler in patients with resistant hypertension demonstrated substantial reductions in both office and ambulatory blood pressure to 12-month postimplantation. There was a common, but manageable, adverse effect of upstream iliac venous stenosis causing ipsilateral lower limb oedema. There were no renal safety concerns. The mechanism of action is proposed to be mechanical by provision of a low-pressure parallel circuit attached to the high-pressure arterial system though detailed physiological evaluation is currently lacking.
SUMMARY: Preliminary data using the ROX coupler to form a central arteriovenous anastomosis are very encouraging. Concerns regarding the lack of sham control are to some extent mitigated by immediate on table blood pressure reduction with opening of the coupler and will be further addressed in the ongoing pivotal, sham-controlled ROX CONTROL Hypertension2 study which should provide further robust information regarding efficacy and safety.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app