We have located links that may give you full text access.
No improvement in reducing outliers in coronal axis alignment with patient-specific instrumentation.
Knee Surgery, Sports Traumatology, Arthroscopy 2018 September
PURPOSE AND HYPOTHESIS: Patient-specific instrumentation (PSI) uses 3D preoperative imaging to produce individualized cutting blocks specific to patients' anatomy and according to the preoperative plan with the aim to reduce the number of mechanical leg alignment (MLA) outliers, to improve implant positioning and to decrease surgery time. The primary purpose of this study was to investigate the efficacy of a specific PSI in comparison with standard instrumentation (SI) in reducing the number of MLA outliers. It was hypothesized that the number of MLA outliers would be significantly lower in the PSI group.
METHODS: A multicenter randomized controlled trial was implemented. There were 59 patients in the PSI group and 66 in the SI group. The absolute number of outliers outside the ± 3° target neutral MLA was compared between the groups with a Chi-square test. As secondary outcomes, the Knee Society Score (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were compared between the groups preoperatively and at 90-day follow-up.
RESULTS: There were 15 (26.3%) MLA outliers in the PSI group and 8 (12.3%) in the SI group. The number of outliers was not independent from the group ( X 2 (1) = 3.8, p = 0.04; Relative risk = 1.5). Preoperatively, there were no significant differences between the groups when comparing their KSS and KOOS sub-scores. At 90 days postoperatively, the patients in the SI group showed better KOOS-Quality of Life (KOSS-QOL) in comparison with the PSI group (p < 0.0001).
CONCLUSION: The use of PSI did not significantly reduce the number of MLA outliers in comparison with SI. There were no differences when comparing the achieved mean MLA of both groups.
LEVEL OF EVIDENCE: Level I, prospective randomized controlled trial.
METHODS: A multicenter randomized controlled trial was implemented. There were 59 patients in the PSI group and 66 in the SI group. The absolute number of outliers outside the ± 3° target neutral MLA was compared between the groups with a Chi-square test. As secondary outcomes, the Knee Society Score (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were compared between the groups preoperatively and at 90-day follow-up.
RESULTS: There were 15 (26.3%) MLA outliers in the PSI group and 8 (12.3%) in the SI group. The number of outliers was not independent from the group ( X 2 (1) = 3.8, p = 0.04; Relative risk = 1.5). Preoperatively, there were no significant differences between the groups when comparing their KSS and KOOS sub-scores. At 90 days postoperatively, the patients in the SI group showed better KOOS-Quality of Life (KOSS-QOL) in comparison with the PSI group (p < 0.0001).
CONCLUSION: The use of PSI did not significantly reduce the number of MLA outliers in comparison with SI. There were no differences when comparing the achieved mean MLA of both groups.
LEVEL OF EVIDENCE: Level I, prospective randomized controlled trial.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app