Comparative Study
Journal Article
Multicenter Study
Observational Study
Add like
Add dislike
Add to saved papers

Minilaparoscopy vs Standard Laparoscopy for Sentinel Node Dissection: A Pilot Study.

OBJECTIVE: To compare 3-mm minilaparoscopy and standard 5-mm laparoscopy for sentinel lymph node (SLN) detection in apparent early-stage endometrial cancer (EC).

DESIGN: Retrospective study (Canadian Task Force classification II-2).

SETTING: Two academic research centers.

PATIENTS: Consecutive women with apparent early-stage EC who underwent surgical staging with SLN detection between November 2015 and April 2016.

INTERVENTIONS: The surgical approach was a total laparoscopic extrafascial hysterectomy plus bilateral salpingo-oophorectomy and SLN detection. Systematic lymphadenectomy was performed in selected cases. In all patients, SLN detection was performed with cervical injection of indocyanine green and the use of an optical camera with a near-infrared high-intensity light source for detection of fluorescence imaging. All patients who underwent a minilaparoscopic approach (using one 5-mm scope and three 3-mm ancillary trocars) have been enrolled at the University of Insubria, whereas at the San Gerardo Hospital, standard laparoscopy was performed with one 10-mm scope and three 5-mm ancillary trocars.

MEASUREMENTS AD MAIN RESULTS: A total of 38 patients were enrolled, including 15 (39.5%) in the 3-mm group and 23 (60.5%) in the 5-mm group. No between-group differences were found in terms of demographic and tumor characteristics. Bilateral SLNs were detected in 73.3% of the patients in the 3-mm group and in 73.9% in the 5-mm group. Operative time, blood loss, hemoglobin drop, hospital stay, and the incidence and severity of complications were similar in the 2 groups. One patient (4.3%) in the standard 5-mm group had a positive SLN result (a micrometastasis in the left external iliac SLN). No positive SLNs were detected in the 3-mm group.

CONCLUSION: Minilaparoscopic SLN biopsy appears to be a promising and feasible technique for EC staging. Further research is warranted to investigate the possible benefits of 3-mm instruments in this specific setting.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app