Biological monitoring of exposure to low concentrations of benzene in workers at a metallurgical coke production plant: new insights into S-phenylmercapturic acid and urinary benzene.
Biomarkers : Biochemical Indicators of Exposure, Response, and Susceptibility to Chemicals 2018 Februrary
CONTEXT: Urinary S-phenylmercapturic acid (SPMA) and benzene (U-Ben) are usually measured at the end of the work shift (ES), although their kinetic of elimination is not clearly known.
OBJECTIVE: To investigate SPMA and U-Ben elimination 16 h after the ES, in 93 coke production workers exposed to low benzene concentrations.
MATERIALS AND METHODS: Airborne benzene (A-Ben) was measured by passive samplings, while SPMA, U-Ben, methyl-tert-butyl ether (U-MTBE), cotinine (U-Cot) and creatinine were determined on urine samples collected at ES and before the beginning of the next work shift (next BS).
RESULTS: Median A-Ben concentrations were 17.2 µg/m3 in the personal and 34.7 µg/m3 in the stationary samplings. SPMA was always detectable, whereas U-Ben was below the limit of quantification in 26.7% of the ES and 35.6% of the next BS samples, and U-MTBE in more than the 80.0% of the samples. At both the sampling times, SPMA and U-Ben showed a positive dependence on personal A-Ben, as well as on creatinine and U-Cot values.
DISCUSSION AND CONCLUSION: SPMA and U-Ben at the next BS were dependent on the exposure to low benzene concentrations suffered in the previous work shift, prompting a reconsideration of the urine sampling time recommended by the American Conference Governmental Industrial Hygienists (ACGIH).
OBJECTIVE: To investigate SPMA and U-Ben elimination 16 h after the ES, in 93 coke production workers exposed to low benzene concentrations.
MATERIALS AND METHODS: Airborne benzene (A-Ben) was measured by passive samplings, while SPMA, U-Ben, methyl-tert-butyl ether (U-MTBE), cotinine (U-Cot) and creatinine were determined on urine samples collected at ES and before the beginning of the next work shift (next BS).
RESULTS: Median A-Ben concentrations were 17.2 µg/m3 in the personal and 34.7 µg/m3 in the stationary samplings. SPMA was always detectable, whereas U-Ben was below the limit of quantification in 26.7% of the ES and 35.6% of the next BS samples, and U-MTBE in more than the 80.0% of the samples. At both the sampling times, SPMA and U-Ben showed a positive dependence on personal A-Ben, as well as on creatinine and U-Cot values.
DISCUSSION AND CONCLUSION: SPMA and U-Ben at the next BS were dependent on the exposure to low benzene concentrations suffered in the previous work shift, prompting a reconsideration of the urine sampling time recommended by the American Conference Governmental Industrial Hygienists (ACGIH).
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app