Magnetic resonance elastography is as accurate as liver biopsy for liver fibrosis staging.

BACKGROUND: Liver MR elastography (MRE) is available for the noninvasive assessment of liver fibrosis; however, no previous studies have compared the diagnostic ability of MRE with that of liver biopsy.

PURPOSE: To compare the diagnostic accuracy of liver fibrosis staging between MRE-based methods and liver biopsy using the resected liver specimens as the reference standard.

STUDY TYPE: A retrospective study at a single institution.

POPULATION: In all, 200 patients who underwent preoperative MRE and subsequent surgical liver resection were included in this study. Data from 80 patients were used to estimate cutoff and distributions of liver stiffness values measured by MRE for each liver fibrosis stage (F0-F4, METAVIR system). In the remaining 120 patients, liver biopsy specimens were obtained from the resected liver tissues using a standard biopsy needle.

FIELD STRENGTH/SEQUENCE: 2D liver MRE with gradient-echo based sequence on a 1.5 or 3T scanner was used.

ASSESSMENT: Two radiologists independently measured the liver stiffness value on MRE and two types of MRE-based methods (threshold and Bayesian prediction method) were applied. Two pathologists evaluated all biopsy samples independently to stage liver fibrosis. Surgically resected whole tissue specimens were used as the reference standard.

STATISTICAL TESTS: The accuracy for liver fibrosis staging was compared between liver biopsy and MRE-based methods with a modified McNemar's test.

RESULTS: Accurate fibrosis staging was achieved in 53.3% (64/120) and 59.1% (71/120) of patients using MRE with threshold and Bayesian methods, respectively, and in 51.6% (62/120) with liver biopsy. Accuracies of MRE-based methods for diagnoses of ≥F2 (90-91% [108-9/120]), ≥F3 (79-81% [95-97/120]), and F4 (82-85% [98-102/120]) were statistically equivalent to those of liver biopsy (≥F2, 79% [95/120], P ≤ 0.01; ≥F3, 88% [105/120], P ≤ 0.006; and F4, 82% [99/120], P ≤ 0.017).

DATA CONCLUSION: MRE can be an alternative to liver biopsy for fibrosis staging.

LEVEL OF EVIDENCE: 3. Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1268-1275.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app