We have located links that may give you full text access.
Journal Article
Research Support, N.I.H., Extramural
MEDI+0: Morphology enabled dipole inversion with automatic uniform cerebrospinal fluid zero reference for quantitative susceptibility mapping.
Magnetic Resonance in Medicine 2018 May
PURPOSE: To develop a quantitative susceptibility mapping (QSM) method with a consistent zero reference using minimal variation in cerebrospinal fluid (CSF) susceptibility.
THEORY AND METHODS: The ventricular CSF was automatically segmented on the R2* map. An L2 -regularization was used to enforce CSF susceptibility homogeneity within the segmented region, with the averaged CSF susceptibility as the zero reference. This regularization for CSF homogeneity was added to the model used in a prior QSM method (morphology enabled dipole inversion [MEDI]). Therefore, the proposed method was referred to as MEDI+0 and compared with MEDI in a numerical simulation, in multiple sclerosis (MS) lesions, and in a reproducibility study in healthy subjects.
RESULTS: In both the numerical simulations and in vivo experiments, MEDI+0 not only decreased the susceptibility variation within the ventricular CSF, but also suppressed the artifact near the lateral ventricles. In the simulation, MEDI+0 also provided more accurate quantification compared to MEDI in the globus pallidus, substantia nigra, corpus callosum, and internal capsule. MEDI+0 measurements of MS lesion susceptibility were in good agreement with those obtained by MEDI. Finally, both MEDI+0 and MEDI showed good and similar intrasubject reproducibility.
CONCLUSION: QSM with a minimal variation in ventricular CSF is viable to provide a consistent zero reference while improving image quality. Magn Reson Med 79:2795-2803, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
THEORY AND METHODS: The ventricular CSF was automatically segmented on the R2* map. An L2 -regularization was used to enforce CSF susceptibility homogeneity within the segmented region, with the averaged CSF susceptibility as the zero reference. This regularization for CSF homogeneity was added to the model used in a prior QSM method (morphology enabled dipole inversion [MEDI]). Therefore, the proposed method was referred to as MEDI+0 and compared with MEDI in a numerical simulation, in multiple sclerosis (MS) lesions, and in a reproducibility study in healthy subjects.
RESULTS: In both the numerical simulations and in vivo experiments, MEDI+0 not only decreased the susceptibility variation within the ventricular CSF, but also suppressed the artifact near the lateral ventricles. In the simulation, MEDI+0 also provided more accurate quantification compared to MEDI in the globus pallidus, substantia nigra, corpus callosum, and internal capsule. MEDI+0 measurements of MS lesion susceptibility were in good agreement with those obtained by MEDI. Finally, both MEDI+0 and MEDI showed good and similar intrasubject reproducibility.
CONCLUSION: QSM with a minimal variation in ventricular CSF is viable to provide a consistent zero reference while improving image quality. Magn Reson Med 79:2795-2803, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app