JOURNAL ARTICLE
OBSERVATIONAL STUDY
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

An investigation of fetal behavioural states during maternal sleep in healthy late gestation pregnancy: an observational study.

Journal of Physiology 2017 December 16
KEY POINTS: Fetal behavioural state in healthy late gestation pregnancy is significantly affected by maternal position overnight. Maternal left lateral position is the one most frequently adopted at sleep onset. The maternal position at sleep onset is maintained the longest overnight. Fetal state 1F is more common in maternal supine positions overnight. Fetal state 4F is less common in maternal supine sleep positions. Fetal state and maternal sleep position are independently associated with fetal heart rate variability. Maternal sleep position significantly affects fetal heart rate and heart rate variability and affects circadian fetal heart rate patterns.

ABSTRACT: Fetal behavioural states (FBS) are measures of fetal wellbeing. Maternal position affects FBS with supine position being associated with an increased likelihood of fetal quiescence consistent with the human fetus adapting to a lower oxygen consuming state. Several studies have now confirmed the association between sleep position and risk of late intrauterine death. We designed this study to observe the effects of maternal sleep positions overnight in healthy late gestation pregnancy. Twenty-nine healthy women had continuous fetal ECG recordings overnight. Two blinded observers assigned fetal states in 5 min blocks. Measures of fetal heart rate variability (FHRV) were calculated from ECG beat to beat data. Maternal position was determined from infrared video recording. Compared to state 2F (active sleep), 4F (active awake-high activity) occurred almost exclusively when the mother was in a left or right lateral position. State 1F (quiet sleep) was more common when the mother was supine [odds ratio (OR) 1.30, 95% confidence interval (CI) 1.11-1.52] and less common on the maternal right side with the left being the referent position (OR 0.81, 95% CI, 0.70-0.93). State 4F was more common between 21.00 and 01.00 h than between 01.00 and 07.00 h (OR 2.83, 95% CI 2.32-3.47). In each fetal state, maternal position had significant effects on fetal heart rate and measures of FHRV. In healthy late gestation pregnancy, maternal sleep position affects FBS and heart rate variability. These effects are probably fetal adaptations to positions which may produce a mild hypoxic stress.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app