We have located links that may give you full text access.
Journal Article
Meta-Analysis
Review
Systematic Review
Stapled anastomosis versus hand-sewn anastomosis of gastro/duodenojejunostomy in pancreaticoduodenectomy: A systematic review and meta-analysis.
International Journal of Surgery 2017 December
BACKGROUND: Controversy exists regarding the best anastomotic method for pancreaticoduodenectomy (PD). We aimed to evaluate the perioperative outcomes of PD with stapled anastomosis (SA) versus hand-sewn anastomosis (HA) of gastrojejunostomy or duodenojejunostomy.
METHODS: We conducted a systematic search of electronic information sources, including MEDLINE; EMBASE; CINAHL; the Cochrane Central Register of Controlled Trials (CENTRAL); the World Health Organization International Clinical Trials Registry; ClinicalTrials.gov; ISRCTN Register, and bibliographic reference lists. We applied a combination of free text and controlled vocabulary search adapted to thesaurus headings, search operators and limits in each of the above databases. Delayed gastric emptying (DGE), postoperative pancreatic fistula (POPF), anastomotic bleeding, anastomotic leak, intra-abdominal abscess and mortality were defined as the outcome parameters. Combined overall effect sizes were calculated using fixed-effect or random-effects models.
RESULTS: We identified 1 randomised controlled trial (RCT) and 5 observational studies reporting a total of 890 patients who underwent PD with SA (n = 300) or conventional HA (n = 590). Our analysis demonstrated that SA significantly reduced postoperative DGE (OR: 0.37, 95% CI 0.25-0.54, P < 0.00001) but significantly increased anastomotic bleeding (OR: 13.4, 95% CI 2.96-57.41, P = 0.0007) compared to HA. No significant difference was found in POPF (OR: 0.83, 95% CI 0.56-1.21, P = 0.33); anastomotic leak (OR: 0.50, 95% CI 0.09-3.79, P = 0.58); intra-abdominal abscess (OR: 1.39, 95% CI 0.71-2.70, P = 0.34); or mortality (RD: -0.01, 95% CI 0.03-0.02, P = 0.65) between two groups.
CONCLUSIONS: Our analysis demonstrated that compared to conventional HA, SA may be associated with lower incidence of DGE after PD without increasing the risk of clinically significant POPF, anastomotic leak or mortality. However, it is associated with higher rate of anastomotic bleeding which mandates careful and precise haemostasis of the stapled line. Considering the current limited evidence, no definitive conclusion can be drawn. Future research is required.
METHODS: We conducted a systematic search of electronic information sources, including MEDLINE; EMBASE; CINAHL; the Cochrane Central Register of Controlled Trials (CENTRAL); the World Health Organization International Clinical Trials Registry; ClinicalTrials.gov; ISRCTN Register, and bibliographic reference lists. We applied a combination of free text and controlled vocabulary search adapted to thesaurus headings, search operators and limits in each of the above databases. Delayed gastric emptying (DGE), postoperative pancreatic fistula (POPF), anastomotic bleeding, anastomotic leak, intra-abdominal abscess and mortality were defined as the outcome parameters. Combined overall effect sizes were calculated using fixed-effect or random-effects models.
RESULTS: We identified 1 randomised controlled trial (RCT) and 5 observational studies reporting a total of 890 patients who underwent PD with SA (n = 300) or conventional HA (n = 590). Our analysis demonstrated that SA significantly reduced postoperative DGE (OR: 0.37, 95% CI 0.25-0.54, P < 0.00001) but significantly increased anastomotic bleeding (OR: 13.4, 95% CI 2.96-57.41, P = 0.0007) compared to HA. No significant difference was found in POPF (OR: 0.83, 95% CI 0.56-1.21, P = 0.33); anastomotic leak (OR: 0.50, 95% CI 0.09-3.79, P = 0.58); intra-abdominal abscess (OR: 1.39, 95% CI 0.71-2.70, P = 0.34); or mortality (RD: -0.01, 95% CI 0.03-0.02, P = 0.65) between two groups.
CONCLUSIONS: Our analysis demonstrated that compared to conventional HA, SA may be associated with lower incidence of DGE after PD without increasing the risk of clinically significant POPF, anastomotic leak or mortality. However, it is associated with higher rate of anastomotic bleeding which mandates careful and precise haemostasis of the stapled line. Considering the current limited evidence, no definitive conclusion can be drawn. Future research is required.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app