Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Objective and subjective diagnostic parameters in the fellow eye of unilateral keratoconus.

BMC Ophthalmology 2017 October 7
BACKGROUND: Keratoconus (KC) is usually a bilateral corneal ectatic disease. For significant asymmetric presentation (so called unilateral KC), the fellow eye has the mildest and earliest form of the disease, which is typically called forme fruste keratoconus. The aim of this study was to evaluate the sensitivity and specificity of parameters derived from a Scheimpflug imaging system (Pentacam) as well as the changes in the quality of mesopic vision in the apparently normal fellow eye (forme fruste) to detect the earliest and most sensitive parameters.

METHODS: Patients with clinical keratoconus in one eye and forme fruste keratoconus in the fellow eye were compared to subjects with normal eyes. The patients were examined using a rotating Scheimpflug imaging system (Pentacam).The following parameters were evaluated: keratometry, minimum corneal thickness, pachymetry progression index (PPI), Ambrósio relational thickness (ART), posterior elevation, back difference elevation (BDE) and multimetric D index(D index). Receiver operating characteristic (ROC) curves were analyzed by evaluating the area under the curve (AUC) to detect the sensitivity and specificity of each parameter. Mesopic vision evaluations were performed by contrast sensitivity and glare tests for each group.

RESULTS: A total of 48 patients with clinical keratoconus in one eye and forme fruste keratoconus in the fellow eye and 72normal subjects were evaluated. In the clinical keratoconus eyes, the mean K, back difference elevation (BDE), pachymetric progression index maximum(PPI max), and multimetric D were significantly higher compared to the normal subjects, whereas the corneal pachymetry and Ambrósio relational thickness maximum (ART max) were significantly lower. In the forme fruste eyes, the ROC analysis showed that the AUC values of the mean K, thinnest pachymetry, ARTmax, BDE, D index, and PPI max were 0.82, 0.61, 0.88, 0. 67, and 0.64, respectively. The contrast sensitivity and glare tests were significantly affected in the forme fruste cases.

CONCLUSION: In forme fruste keratoconus eyes, the ART max is considered a highly sensitive objective parameter. Contrast sensitivity and glare is an important subjective test, which is affected in forme fruste patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app