Reproducibility of differential renal function measurement using technetium-99m-ethylenedicysteine dynamic renal scintigraphy: a French prospective multicentre study.
Nuclear Medicine Communications 2018 January
OBJECTIVE: Dynamic renal scintigraphy remains the gold standard for assessing differential renal function (DRF). Recently, technetium-99m-ethylenedicysteine (Tc-EC) was shown to be valuable and had similar quality images as technetium-99m-mercaptoacetyltriglycine (Tc-MAG3). However, its reproducibility has never been confirmed. The aim of this study was to perform the first evaluation of Tc-EC reproducibility for assessing DRF in children who were referred for hydronephrosis or urinary tract dilatation.
PATIENTS AND METHODS: A total of 109 patients from three French nuclear medicine departments prospectively underwent dynamic renal scintigraphy with Tc-EC. DRF reproducibility was assessed by different pairs of raters using a multilevel design that integrated local and centralized predefined procedures.
RESULTS: Both local and centralized procedures yielded near-excellent inter-rater agreements, with all of the intraclass correlation coefficient values over 0.998. Bland-Altman plots showed a systematic bias of less than 1%, with the corresponding limits of agreements not exceeding the 5% threshold cut-off value that corresponds to the clinical definition of acceptable limits for this purpose. Intrarater agreements were also good to excellent.
CONCLUSION: This prospective multicentre study showed that Tc-EC is highly reproducible for assessing DRF in a standard paediatric population, thus validating its use as an alternative to Tc-MAG3 in this setting.
PATIENTS AND METHODS: A total of 109 patients from three French nuclear medicine departments prospectively underwent dynamic renal scintigraphy with Tc-EC. DRF reproducibility was assessed by different pairs of raters using a multilevel design that integrated local and centralized predefined procedures.
RESULTS: Both local and centralized procedures yielded near-excellent inter-rater agreements, with all of the intraclass correlation coefficient values over 0.998. Bland-Altman plots showed a systematic bias of less than 1%, with the corresponding limits of agreements not exceeding the 5% threshold cut-off value that corresponds to the clinical definition of acceptable limits for this purpose. Intrarater agreements were also good to excellent.
CONCLUSION: This prospective multicentre study showed that Tc-EC is highly reproducible for assessing DRF in a standard paediatric population, thus validating its use as an alternative to Tc-MAG3 in this setting.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app