We have located links that may give you full text access.
Relevance of sample preparation for flow cytometry.
INTRODUCTION: Flow cytometry is a useful tool for diagnosis and minimal residual disease (MRD) study of hematological diseases. Standard sample preparation protocols are characterized by stain-lyse-wash (SLW). To prevent nonspecific bindings and achieve high sensitivity in MRD studies, lyse-wash-stain-wash (LWSW) is required. To our knowledge, no comparison between the two methods has been performed.
METHODS: We compared mean fluorescence intensity (MFI), stain index, signal-to-noise ratio, and percentage of positive cells of 104 antibodies and of 13 selected antibodies tested in 10 samples simultaneously prepared with the two methods.
RESULTS: MFI and percentages of positive cells obtained by the two methods did not show significant differences and showed a very high correlation. Stain index and signal-to-noise ratio presented higher values for kappa and lambda surface chains in LWSW samples and a trend of higher values for the other antibodies in SLW samples.
CONCLUSIONS: We suggest to use LWSW method also at diagnosis to obtain more comparable antibody intensity expressions when samples from the same patient are processed for MRD evaluation after bulk lysis. Moreover, LWSW can prevent nonspecific bindings, shows no differences in the identification and quantitation of the populations of interest, and reduces acquisition of cell debris.
METHODS: We compared mean fluorescence intensity (MFI), stain index, signal-to-noise ratio, and percentage of positive cells of 104 antibodies and of 13 selected antibodies tested in 10 samples simultaneously prepared with the two methods.
RESULTS: MFI and percentages of positive cells obtained by the two methods did not show significant differences and showed a very high correlation. Stain index and signal-to-noise ratio presented higher values for kappa and lambda surface chains in LWSW samples and a trend of higher values for the other antibodies in SLW samples.
CONCLUSIONS: We suggest to use LWSW method also at diagnosis to obtain more comparable antibody intensity expressions when samples from the same patient are processed for MRD evaluation after bulk lysis. Moreover, LWSW can prevent nonspecific bindings, shows no differences in the identification and quantitation of the populations of interest, and reduces acquisition of cell debris.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app