EVALUATION OF RADIATION ABSORBED DOSE AND IMAGE QUALITY IN DIFFERENT RETROSPECTIVE-ECG GATING ACQUISITION METHODS OF CARDIAC CT ANGIOGRAPHY.
Radiation Protection Dosimetry 2018 Februrary 2
Cardiac computed tomography angiography (CCTA) studies have risen concern of radiobiological effects over the patients. Therefore, estimating radiation doses absorbed during CCTA is important. In this study, we compared radiation dose and image quality by using three different retrospective electrocardiography (ECG) protocols. A total of 123 patients undergoing CCTA were divided in three different groups. We used full-dose modulation (CareDose4D) technique in group (1); fixed tube current 200 mAs for group (2); and in group (3), chest circumference was used to adapt tube current (180-200 mAs) and tube potential (100-120 kVp). For groups (1) and (2), tube potential adapted depends on body mass index (BMI) in which it was 100 kVp for BMI < 27 kg/m2, and 120 kVp for BMI ≥ 27 kg/m2. Quantitive assessment of image quality was calculated by measuring signal intensity (SI) and image noise (IN) in the proximal segments of aorta root on left and right coronary arteries. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were also calculated by using SI and IN. Two experienced radiologists using a 4-point scale assessed the subjective image quality. Our results show that in group (1), the mean effective dose was 4.46 mSv (range: 1.75-8.6 mSv) and for group (2), the mean effective radiation dose was 5.07 mSv (range: 2.57-9.74 mSv) and in group (3), the mean effective dose was 5.85 mSv (range: 3.36-12.17 mSv). Group (1) representing 12% and 23% decrease in radiation dose comparing by groups (2) and (3). In multivariate analysis, adjusting for BMI, radiation dose for patients with BMI < 27 kg/m2 was significantly different; 2.53 mSv for group (1) compared to 3.54 mSv in group (2) and 5.207 in group (3) (p < 0.0001). In addition, lowering tube potential from 120 to 100 kVp in 200 mAs fixed tube current, represents 27% decrease in radiation dose. The quantitative image quality (IN, SI, SNR and CNR) was not statistically significant among the groups. To sum up, Retrospective-ECG gating may reduce radiation dose by using automatic tube current modulation and 100kVp tube potential with preservation of image quality in patient's whose BMI < 27 kg/m2.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app