We have located links that may give you full text access.
Correction of stopping power and LET quenching for radiophotoluminescent glass dosimetry in a therapeutic proton beam.
Physics in Medicine and Biology 2017 November 10
To measure the absorbed dose to water D w in proton beams using a radiophotoluminescent glass dosimeter (RGD), a method with the correction for the change of the mass stopping power ratio (SPR) and the linear energy transfer (LET) dependence of radiophotoluminescent efficiency [Formula: see text] is proposed. The calibration coefficient in terms of D w for RGDs (GD-302M, Asahi Techno Glass) was obtained using a 60 Co γ-ray. The SPR of water to the RGD was calculated by Monte Carlo simulation, and [Formula: see text] was investigated experimentally using a 70 MeV proton beam. For clinical usage, the residual range R res was used as a quality index to determine the correction factor for the beam quality [Formula: see text] and the LET quenching effect of the RGD [Formula: see text]. The proposed method was evaluated by measuring D w at different depths in a 200 MeV proton beam. For both non-modulated and modulated proton beams, [Formula: see text] decreases rapidly where R res is less than 4 cm. The difference in [Formula: see text] between a non-modulated and a modulated proton beam is less than 0.5% for the R res range from 0 cm to 22 cm. [Formula: see text] decreases rapidly at a LET range from 1 to 2 keV µm-1 . In the evaluation experiments, D w using RGDs, [Formula: see text] showed good agreement with that obtained using an ionization chamber and the relative difference was within 3% where R res was larger than 1 cm. The uncertainty budget for [Formula: see text] in a proton beam was estimated to investigate the potential of RGD postal dosimetry in proton therapy. These results demonstrate the feasibility of RGD dosimetry in a therapeutic proton beam and the general versatility of the proposed method. In conclusion, the proposed methodology for RGDs in proton dosimetry is applicable where R res > 1 cm and the RGD is feasible as a postal audit dosimeter for proton therapy.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app