Urinary EN-2 to predict prostate cancer: Systematic review and meta-analysis.
Revista da Associação Médica Brasileira 2017 July
INTRODUCTION: Prostate cancer is the second type of cancer diagnosed and the fifth cause of death in men worldwide. Early diagnosis helps to control disease progression. Currently, prostate specific antigen is the standard biomarker, as it has a broad scope of identification and, thus, new and more specific biomarkers must be studied.
OBJECTIVE: To evaluate the accuracy of engrailed-2 protein (EN2) in urine as a prostate cancer biomarker.
METHOD: A comprehensive search was conducted in the period from January 2005 to July 2016 using the following electronic databases: Medline (PubMed), Embase, Cochrane Library and Lilacs. The keywords used in the databases were: "engrailed-2," "EN2," "prostatic neoplasms." The search was limited to humans and there was no language restriction. Critical appraisal of the included studies was performed according to Quadas-2. Statistical analysis was performed using Meta-DiSc® and RevMan 5.3 softwares.
RESULTS: A total of 248 studies were identified. After title and abstract screening, 231 studies were removed. A total of 17 studies were read in full and two studies were included in the meta-analysis. The pooled sensitivity was 66% (95CI 0.56-0.75) and specificity was 89% (95CI 0.86-0.92). The DOR was 15.08 (95CI 8.43-26.97).
CONCLUSION: The EN2 test showed high specificity (89%) and low sensitivity (66%).
OBJECTIVE: To evaluate the accuracy of engrailed-2 protein (EN2) in urine as a prostate cancer biomarker.
METHOD: A comprehensive search was conducted in the period from January 2005 to July 2016 using the following electronic databases: Medline (PubMed), Embase, Cochrane Library and Lilacs. The keywords used in the databases were: "engrailed-2," "EN2," "prostatic neoplasms." The search was limited to humans and there was no language restriction. Critical appraisal of the included studies was performed according to Quadas-2. Statistical analysis was performed using Meta-DiSc® and RevMan 5.3 softwares.
RESULTS: A total of 248 studies were identified. After title and abstract screening, 231 studies were removed. A total of 17 studies were read in full and two studies were included in the meta-analysis. The pooled sensitivity was 66% (95CI 0.56-0.75) and specificity was 89% (95CI 0.86-0.92). The DOR was 15.08 (95CI 8.43-26.97).
CONCLUSION: The EN2 test showed high specificity (89%) and low sensitivity (66%).
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app