Add like
Add dislike
Add to saved papers

Multiple Myeloma Cell Drug Responses Differ in Thermoplastic vs PDMS Microfluidic Devices.

Analytical Chemistry 2017 November 8
Poly(dimethylsiloxane) (PDMS) is a commonly used elastomer for fabricating microfluidic devices, but it has previously been shown to absorb hydrophobic molecules. Although this has been demonstrated for molecules such as estrogen and Nile Red, the absorption of small hydrophobic molecules in PDMS specifically used to treat cancer and its subsequent impact on cytotoxicity measurements and assays have not been investigated. This is critical for the development of microfluidic chemosensitivity and resistance assay (CSRA) platforms that have shown potential to help guide clinical therapy selection and which rely on the accuracy of the readout involving interactions between patient-derived cells and cancer drugs. It is thus important to address the issue of drug absorption into device material. We investigated drug absorption into microfluidic devices by treating multiple myeloma (MM) tumor cells with two MM drugs (bortezomib (BTZ) and carfilzomib (CFZ)) in devices fabricated using three different materials (polystyrene (PS), cyclo-olefin polymer (COP), and PDMS). Half-maximal inhibitory concentrations (IC50) were obtained for each drug-material combination, and an increase in IC50 of ∼4.3× was observed in PDMS devices compared to both thermoplastic devices. Additionally, each MM drug was exposed to polymer samples, and samples were analyzed using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to characterize adsorption and absorption of the drugs into each material. ToF-SIMS data showed the bias observed in IC50 values found in PDMS devices was directly related to the absorption of drug during dose-response experiments. Specifically, BTZ and CFZ absorption in both PS and COP were all in the range of ∼100-300 nm, whereas BTZ and CFZ absorption in PDMS was ∼5.0 and ∼3.5 μm, respectively. These results highlight the biases that exist in PDMS devices and the importance of material selection in microfluidic device design, especially in applications involving drug cytotoxicity and hydrophobic molecules.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app