Bone Age Assessments by Quantitative Ultrasound (SonicBone) and Hand X-ray Based Methods are Comparable.
Israel Medical Association Journal : IMAJ 2017 September
BACKGROUND: Bone maturation is currently assessed by subjective and automated radiography.
OBJECTIVES: To evaluate the concordance and reproducibility of a quantitative ultrasound (QUS) based device versus X-ray based methods.
METHODS: The study population comprised 150 children, 76 males, 4-17 years of age. X-ray scans were evaluated according to wrist, carpal and phalanx areas for bone age. QUS was performed by the the BAUS™ device (SonicBone, Rishon Lezion, Israel), using speed-of-sound (SOS) and distance attenuation factor (ATN) in similar areas. Data from 100 subjects were used to establish the device conversion equation, and 50 measurements were assigned to assess inter-modality agreement.
RESULTS: BAUS showed high repeatability performance, 0.73% relative standard deviation for SOS and 3.5% for ATN. R2 for the conversion equation, including gender, SOS, and ATN, was 0.80 for all methods (P < 0.001). There was no significant bias in bone age assessments.
CONCLUSIONS: Bone age assessment by SonicBone is comparable to the assessment by X-ray based methods.
OBJECTIVES: To evaluate the concordance and reproducibility of a quantitative ultrasound (QUS) based device versus X-ray based methods.
METHODS: The study population comprised 150 children, 76 males, 4-17 years of age. X-ray scans were evaluated according to wrist, carpal and phalanx areas for bone age. QUS was performed by the the BAUS™ device (SonicBone, Rishon Lezion, Israel), using speed-of-sound (SOS) and distance attenuation factor (ATN) in similar areas. Data from 100 subjects were used to establish the device conversion equation, and 50 measurements were assigned to assess inter-modality agreement.
RESULTS: BAUS showed high repeatability performance, 0.73% relative standard deviation for SOS and 3.5% for ATN. R2 for the conversion equation, including gender, SOS, and ATN, was 0.80 for all methods (P < 0.001). There was no significant bias in bone age assessments.
CONCLUSIONS: Bone age assessment by SonicBone is comparable to the assessment by X-ray based methods.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app