We have located links that may give you full text access.
Insertion torque and Periotest values are important factors predicting outcome after orthodontic miniscrew placement.
INTRODUCTION: Approximately 14% of orthodontic anchor screws (miniscrews) become dislodged regardless of the accuracy of placement. It is therefore important to investigate the factors causing dislodgement. We evaluated the stability of miniscrews after placement to identify factors influencing outcome in orthodontic treatment using miniscrews.
METHODS: We investigated 120 miniscrews (Dual-top Auto Screw III; Jeil Medical, Seoul, Korea) (diameter, 1.4 mm; length, 6 mm) placed on the buccal or lingual side between the maxillary second premolar and the first molar in women. Patient age and rate and time of screw dislodgement were examined. Insertion torque values and Periotest (Tokyo Dental Industrial, Tokyo, Japan) measurements indicating horizontal and vertical mobility of the inserted screws were compared between groups with and without dislodgement (failure and success groups, respectively).
RESULTS: Mean insertion torque values were 10.7 ± 1.9 N·cm and 8.5 ± 2.1 N·cm in the failure and success groups, respectively. Cortical bone thickness measurements (success group, 1.34 ± 0.35 mm; failure group, 0.99 ± 0.09 mm) were significantly higher, whereas Periotest values at placement (success group, horizontal, 4.9 ± 1.4; vertical, 4.7 ± 1.3; failure group, horizontal, 7.0 ± 0.8; vertical, 7.1 ± 0.9) were significantly lower in the success group than in the failure group.
CONCLUSIONS: The Periotest value, together with insertion torque and cortical bone thickness, could serve as an index of initial stability for predicting the outcome of miniscrew placement.
METHODS: We investigated 120 miniscrews (Dual-top Auto Screw III; Jeil Medical, Seoul, Korea) (diameter, 1.4 mm; length, 6 mm) placed on the buccal or lingual side between the maxillary second premolar and the first molar in women. Patient age and rate and time of screw dislodgement were examined. Insertion torque values and Periotest (Tokyo Dental Industrial, Tokyo, Japan) measurements indicating horizontal and vertical mobility of the inserted screws were compared between groups with and without dislodgement (failure and success groups, respectively).
RESULTS: Mean insertion torque values were 10.7 ± 1.9 N·cm and 8.5 ± 2.1 N·cm in the failure and success groups, respectively. Cortical bone thickness measurements (success group, 1.34 ± 0.35 mm; failure group, 0.99 ± 0.09 mm) were significantly higher, whereas Periotest values at placement (success group, horizontal, 4.9 ± 1.4; vertical, 4.7 ± 1.3; failure group, horizontal, 7.0 ± 0.8; vertical, 7.1 ± 0.9) were significantly lower in the success group than in the failure group.
CONCLUSIONS: The Periotest value, together with insertion torque and cortical bone thickness, could serve as an index of initial stability for predicting the outcome of miniscrew placement.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app