Comparative Study
Journal Article
Multicenter Study
Add like
Add dislike
Add to saved papers

Short-Term Outcome and Hemodynamic Performance of Next-Generation Self-Expanding Versus Balloon-Expandable Transcatheter Aortic Valves in Patients With Small Aortic Annulus: A Multicenter Propensity-Matched Comparison.

BACKGROUND: Surgical aortic valve replacement in patients with small annular dimensions is challenging because they are at increased risk for prosthesis-patient mismatch and impaired outcomes. Transcatheter aortic valve replacement might be a good alternative; however, comparative data on different transcatheter heart valves are missing.

METHODS AND RESULTS: This multicenter, propensity score-matched study compared hemodynamics and early clinical outcomes in 246 patients with an aortic annulus area <400 mm2 undergoing transcatheter aortic valve replacement with either a self-expanding transcatheter heart valve (Symetis ACURATE neo, n=129) or a balloon-expandable transcatheter heart valve (Edwards SAPIEN 3, n=117). The 1:1 propensity score matching resulted in 92 matched pairs. For ACURATE neo versus SAPIEN 3-treated patients, 30-day mortality (0.0% versus 1.0%), 1-year mortality (8.3% versus 13.3%), incidence of stroke (3.3% versus 2.2%), life-threatening bleeding (1.1% versus 1.1%), and major vascular complications (2.2% versus 6.5%), as well as pacemaker implantation rate (12.0% versus 15.2%), were similar. Paravalvular regurgitation ≥moderate was rare in both groups (4.5% versus 3.6%). The ACURATE neo presented lower mean transvalvular gradients (9.3 versus 14.5 mm Hg; P <0.001), larger indexed effective orifice areas (0.96 versus 0.80 cm2 /m2 ; P =0.003), and lower rates of severe prosthesis-patient mismatch (3% versus 22%; P =0.004). Hemodynamics were sustained at 1-year follow-up.

CONCLUSIONS: Albeit a similar safety profile with low clinical event rates, transcatheter aortic valve replacement with the ACURATE neo valve resulted in lower transvalvular gradients and consequently less prosthesis-patient mismatch compared with the SAPIEN 3 in patients with small annulus. These results emphasize the need of careful prosthesis selection in each individual patient.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app