COMPARATIVE STUDY
JOURNAL ARTICLE
REVIEW
Add like
Add dislike
Add to saved papers

Single vs two implant-retained overdentures for edentulous mandibles: a systematic review.

PURPOSE: To compare prosthesis and implant failure, patient satisfaction, prosthetic complications and peri-implant marginal bone loss of mandibular overdentures (IOD) supported by a single or two implants.

MATERIALS AND METHODS: Manual and electronic database (PubMed and Cochrane) searches were performed to identify randomised controlled trials, without language restriction, comparing single vs two implant supported mandibular overdentures. Two investigators extracted data independently. The Cochrane tool was used for assessing the quality of included studies. Meta-analyses were performed for the included RCTs.

RESULTS: Six publications corresponding to four RCTs were identified. Three RCTs (corresponding to five publications) were included and one trial was excluded. Follow-ups in function were 1, 3 and 5 years after loading. All included studies were considered to be at a high risk of bias. The pooled result revealed more prosthesis failures at overdentures supported by two implants at 1 year (three trials) (P = 0.02; Risk Difference: -0.12, 95% CI: -0.22, -0.02), however, there were non-significant differences at 3 years (two trials) (P = 0.22; Risk Difference: -0.32, 95% CI: -0.83, 0.19) and at 5 years (one trial) (P = 0.95; Risk Difference: 0.01, 95% CI: -0.22, 0.24). Regarding implant failures, there were more implant losses in overdentures supported by two implants at 1 year (three trials) (P = 0.02; Risk Difference: -0.12, 95% CI: -0.22, -0.02) and at 5 years (one trial) (P = 0.95; Risk Difference: -0.15, 95% CI: -0.28, -0.02), however, there were non-significant difference at 3 years (two trials) (P = 0.2; Risk Difference: -0.33, 95% CI: -0.84, 0.18). After 5 years in function, meta-analyses revealed that there were non-significant differences regarding overall prosthetic complications when mandibular overdentures supported by a single implant were compared with overdentures supported by two implants (P = 0.43; RD: 0.04, 95% CI: -0.06, 0.15).

CONCLUSION: Mandibular overdentures retained by a single implant have comparable results to those retained by two implants. However, this should be interpreted with caution as all the included studies were considered at a high risk of bias.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app