We have located links that may give you full text access.
Endoscopic anterior component separation: a novel technical approach.
PURPOSE: Open anterior release of the external oblique fascia to enable midline closure of large abdominal wall defects is associated with relevant morbidity due to extensive subcutaneous dissection. Using endoscopic techniques, wound complications can be minimized. However, identification of the correct entry point (e.g. for balloon trocar insertion) can be challenging especially in adipose patients. We therefore present a technical modification facilitating the entire procedure.
METHODS: A novel technique for endoscopic anterior component separation using a trocar system allowing blunt and sharp dissection under direct vision is described. This brief communication also contains our initial experience and learning curve with this novel approach.
RESULTS: Endoscopic release of the external oblique fascia was successfully performed 29 times in a total of 15 patients. Body mass index accounted for 30.8 kg/m2 (median; range 21.6-42.5). Transverse width of midline defect accounted for 7 cm (median; range 4-12). Subsequent hernia repair was successfully done using sublay mesh reinforcement (n = 13) or a laparoscopic intraperitoneal onlay mesh procedure (n = 2) with midline closure in all cases. One hematoma was seen at site of release managed conservatively.
CONCLUSIONS: Using a trocar system allowing blunt and sharp dissection under direct vision may be a viable option for the endoscopic anterior component separation.
METHODS: A novel technique for endoscopic anterior component separation using a trocar system allowing blunt and sharp dissection under direct vision is described. This brief communication also contains our initial experience and learning curve with this novel approach.
RESULTS: Endoscopic release of the external oblique fascia was successfully performed 29 times in a total of 15 patients. Body mass index accounted for 30.8 kg/m2 (median; range 21.6-42.5). Transverse width of midline defect accounted for 7 cm (median; range 4-12). Subsequent hernia repair was successfully done using sublay mesh reinforcement (n = 13) or a laparoscopic intraperitoneal onlay mesh procedure (n = 2) with midline closure in all cases. One hematoma was seen at site of release managed conservatively.
CONCLUSIONS: Using a trocar system allowing blunt and sharp dissection under direct vision may be a viable option for the endoscopic anterior component separation.
Full text links
Trending Papers
Acute and non-acute decompensation of liver cirrhosis (47/130).Liver International : Official Journal of the International Association for the Study of the Liver 2024 March 2
Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Diseases: 2024 Update by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM).Clinical Infectious Diseases 2024 March 6
Status epilepticus: what's new for the intensivist.Current Opinion in Critical Care 2024 Februrary 15
Administration of methylene blue in septic shock: pros and cons.Critical Care : the Official Journal of the Critical Care Forum 2024 Februrary 17
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app