We have located links that may give you full text access.
Improved Calcium Scoring at Dual-Energy Computed Tomography Angiography Using a High-Z Contrast Element and Novel Material Separation Technique.
OBJECTIVES: The aim of this study was to compare the accuracy of existing dual-energy computed tomography (CT) angiography coronary artery calcium scoring methods to those obtained using an experimental tungsten-based contrast material and a recently described contrast material extraction process (CMEP).
METHODS: Phantom coronary arteries of varied diameters, with different densities and arcs of simulated calcified plaque, were sequentially filled with water, iodine, and tungsten contrast materials and scanned within a thorax phantom at rapid-kVp-switching dual-energy CT. Calcium and contrast density images were obtained by material decomposition (MD) and CMEP. Relative calcium scoring errors among the 4 reconstructed datasets were compared with a ground truth, 120-kVp dataset.
RESULTS: Compared with the 120-kVp dataset, tungsten CMEP showed a significantly lower mean absolute error in calcium score (6.2%, P < 0.001) than iodine CMEP, tungsten MD, and iodine MD (9.9%, 15.7%, and 40.8%, respectively).
CONCLUSIONS: Novel contrast elements and material separation techniques offer improved coronary artery calcium scoring accuracy and show potential to improve the use of dual-energy CT angiography in a clinical setting.
METHODS: Phantom coronary arteries of varied diameters, with different densities and arcs of simulated calcified plaque, were sequentially filled with water, iodine, and tungsten contrast materials and scanned within a thorax phantom at rapid-kVp-switching dual-energy CT. Calcium and contrast density images were obtained by material decomposition (MD) and CMEP. Relative calcium scoring errors among the 4 reconstructed datasets were compared with a ground truth, 120-kVp dataset.
RESULTS: Compared with the 120-kVp dataset, tungsten CMEP showed a significantly lower mean absolute error in calcium score (6.2%, P < 0.001) than iodine CMEP, tungsten MD, and iodine MD (9.9%, 15.7%, and 40.8%, respectively).
CONCLUSIONS: Novel contrast elements and material separation techniques offer improved coronary artery calcium scoring accuracy and show potential to improve the use of dual-energy CT angiography in a clinical setting.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app