Spinal Ischemia in Thoracic Aortic Procedures: Impact of Radiculomedullary Artery Distribution.
Annals of Thoracic Surgery 2017 December
BACKGROUND: The aim of this study was to assess the influence of thoracic anterior radiculomedullary artery (tARMA) distribution on spinal cord perfusion in a thoracic aortic surgical model.
METHODS: Twenty-six pigs (34 ± 3 kg; study group, n = 20; sham group, n = 6) underwent ligation of the left subclavian artery and thoracic segmental arteries. End points were spinal cord perfusion pressure (SCPP), regional spinal cord blood flow (SCBF), and neurologic outcome with an observation time of 3 hours. tARMA distribution patterns tested for an effect on end points included (1) maximum distance between any 2 tARMAs within the treated aortic segment (0 or 1 segment = small-distance group; >1 segment = large-distance group) and (2) distance between the end of the treated aortic segment and the first distal tARMA (at the level of the distal simulated stent-graft end = group 0; gap of 1 or more segments = group ≥1).
RESULTS: The number of tARMA ranged from 3 to 13 (mean, 8). In the large-distance group, SCBF dropped from 0.48 ± 0.16 mL/g/min to 0.3 ± 0.08 mL/g/min (p < 0.001). We observed no detectable SCBF drop in the small-distance group: 0.2 ± 0.05 mL/g/min at baseline to 0.23 ± 0.05 mL/g/min immediately after clamping (p = 0.147). SCBF increased from 0.201 ± 0.055 mL/g/min at baseline to 0.443 ± 0.051 mL/g/min at 3 hours postoperatively (p < 0.001) only in the small-distance group.
CONCLUSIONS: We demonstrate experimental data showing that distribution patterns of tARMAs correlate with the degree of SCBF drop and insufficient reactive parenchymal hyperemia in aortic procedures. Individual ARMA distribution patterns along the treated aortic segment could help us predict the individual risk of spinal ischemia.
METHODS: Twenty-six pigs (34 ± 3 kg; study group, n = 20; sham group, n = 6) underwent ligation of the left subclavian artery and thoracic segmental arteries. End points were spinal cord perfusion pressure (SCPP), regional spinal cord blood flow (SCBF), and neurologic outcome with an observation time of 3 hours. tARMA distribution patterns tested for an effect on end points included (1) maximum distance between any 2 tARMAs within the treated aortic segment (0 or 1 segment = small-distance group; >1 segment = large-distance group) and (2) distance between the end of the treated aortic segment and the first distal tARMA (at the level of the distal simulated stent-graft end = group 0; gap of 1 or more segments = group ≥1).
RESULTS: The number of tARMA ranged from 3 to 13 (mean, 8). In the large-distance group, SCBF dropped from 0.48 ± 0.16 mL/g/min to 0.3 ± 0.08 mL/g/min (p < 0.001). We observed no detectable SCBF drop in the small-distance group: 0.2 ± 0.05 mL/g/min at baseline to 0.23 ± 0.05 mL/g/min immediately after clamping (p = 0.147). SCBF increased from 0.201 ± 0.055 mL/g/min at baseline to 0.443 ± 0.051 mL/g/min at 3 hours postoperatively (p < 0.001) only in the small-distance group.
CONCLUSIONS: We demonstrate experimental data showing that distribution patterns of tARMAs correlate with the degree of SCBF drop and insufficient reactive parenchymal hyperemia in aortic procedures. Individual ARMA distribution patterns along the treated aortic segment could help us predict the individual risk of spinal ischemia.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app