Add like
Add dislike
Add to saved papers

Harmonizing the pixel size in retrospective computed tomography radiomics studies.

Consistent pixel sizes are of fundamental importance for assessing texture features that relate intensity and spatial information in radiomics studies. To correct for the effects of variable pixel sizes, we combined image resampling with Butterworth filtering in the frequency domain and tested the correction on computed tomography (CT) scans of lung cancer patients reconstructed 5 times with pixel sizes varying from 0.59 to 0.98 mm. One hundred fifty radiomics features were calculated for each preprocessing and field-of-view combination. Intra-patient agreement and inter-patient agreement were compared using the overall concordance correlation coefficient (OCCC). To further evaluate the corrections, hierarchical clustering was used to identify patient scans before and after correction. To assess the general applicability of the corrections, they were applied to 17 CT scans of a radiomics phantom. The reduction in the inter-scanner variability relative to non-small cell lung cancer patient scans was quantified. The variation in pixel sizes caused the intra-patient variability to be large (OCCC <95%) relative to the inter-patient variability in 79% of the features. However, with the resampling and filtering corrections, the intra-patient variability was relatively large in only 10% of the features. With the filtering correction, 8 of 8 patients were correctly clustered, in contrast to only 2 of 8 without the correction. In the phantom study, resampling and filtering the images of a rubber particle cartridge substantially reduced variability in 61% of the radiomics features and substantially increased variability in only 6% of the features. Surprisingly, resampling without filtering tended to increase the variability. In conclusion, applying a correction based on resampling and Butterworth low-pass filtering in the frequency domain effectively reduced variability in CT radiomics features caused by variations in pixel size. This correction may also reduce the variability introduced by other CT scan acquisition parameters.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app