Position statement by the Pelvic Floor Society on behalf of the Association of Coloproctology of Great Britain and Ireland on the use of mesh in ventral mesh rectopexy.

Colorectal Disease 2020 October
The following position statement forms part of a response to the current concerns regarding use of mesh to perform rectal prolapse surgery. It highlights the actions being pursued by the Pelvic Floor Society (TPFS) regarding clinical governance in relation to ventral mesh rectopexy (VMR). The following are summary recommendations. Available evidence suggests that mesh morbidity for VMR is far lower than that seen in transvaginal procedures (the main subject of current concern) and lower than that observed following other abdomino-pelvic procedures for urogenital prolapse, e.g. laparoscopic sacrocolpopexy. VMR should be performed by adequately trained surgeons who work within a multidisciplinary team (MDT) framework. Within this, it is mandatory to discuss all patients considered for surgery at an MDT meeting. Clinical outcomes of surgery and any complications resulting from surgery should be recorded in the TPFS-hosted national database (registry) available for this purpose; in addition, all patients should be considered for entry into ongoing and planned UK/European randomized studies where this is feasible. A move towards accreditation of UK units performing VMR will improve performance and outcomes in the long term. An enhanced programme of training including staged porcine, cadaveric and preceptorship sessions will ensure the competence of surgeons undertaking VMR. Enhanced consent forms and patient information booklets are being developed, and these will help both surgeons and patients. There is weak observational evidence that technical aspects of the procedure can be optimized to reduce morbidity rates. Suture material choice may contribute towards morbidity. The available evidence is insufficient to support the use of one mesh over another (biologic vs synthetic); however, the use of polyester mesh is associated with increased morbidity.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app