We have located links that may give you full text access.
JOURNAL ARTICLE
MULTICENTER STUDY
Complications Associated With Implantable Cardioverter Defibrillators in Adults With Congenital Heart Disease or Left Ventricular Noncompaction Cardiomyopathy (From the NCDR ® Implantable Cardioverter-Defibrillator Registry).
American Journal of Cardiology 2017 November 16
Patients with childhood heart disease are living longer and entering adulthood, and may undergo implantable cardioverter-defibrillator (ICD) implantation to reduce the risk of sudden death. We evaluated the characteristics of adult patients with congenital heart disease or left ventricular noncompaction cardiomyopathy (LVNC) in the National Cardiovascular Disease Registry ICD Registry and determined ICD-related in-hospital complications. Patients with LVNC or transposition of the great arteries, tetralogy of Fallot, Ebstein's anomaly, atrial septal defect, ventricular septal defect, or common ventricle were identified in the registry. In-hospital complications were compared among different diagnoses using the chi-square test for categorical variables and the F-test in analyses of variance for continuous variables. A total of 3,077 patients were identified. The mean age was 48.0 ± 16.0 years, and 39.9% were female. Single-chamber ICDs were implanted in 25.2%, dual chamber in 41.9%, and cardiac resynchronization in 30.8%. Intraprocedural or postprocedural complications occurred in 70 patients (2.3%); there were 6 in-hospital deaths (0.2%). The most frequent complications were acute lead dislodgments, pneumothorax, and hematomas. Patients with Ebstein's anomaly had the greatest complication rate (8.3%, p = 0.03). The complication rate was 1.55% in single-chamber devices, 1.86% in dual chamber, and 3.5% in cardiac resynchronization (p < 0.001). For initial implants, the complication rate was 2.55%, 1.62% in generator replacements, and 8.77% in lead revisions (p = 0.001). In conclusion, in this large contemporary adult cohort of congenital heart disease and LVNC patients who underwent ICD implant procedures, periprocedural complication rates were low. Lead-related risks predominated.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app