We have located links that may give you full text access.
A novel leadless, miniature implantable Tibial Nerve Neuromodulation System for the management of overactive bladder complaints.
Neurourology and Urodynamics 2018 March
BACKGROUND: Overactive bladder is a chronic condition affecting lower urinary tract function that has a significant negative impact on QoL.
OBJECTIVE: Evaluation of the BlueWind implantable tibial nerve system performance and safety in refractory OAB.
DESIGN, SETTING, AND PARTICIPANTS INTERVENTION: A 6-month multi-center prospective intervention study.
OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Objective assessment was done by voiding diary parameters including voids/day, volume voided/day, urgency assessment, leaking episodes/day, pads used/day, leak severity, and clinical success defined as a ≥50% reduction in the number of leaks/day or number of voids/day or number of episodes with degree of urgency >2 or a return to <8 voids/day on a 3 Day diary. Subjective assessment was based on OAB-q including HRQL and symptom severity score. Safety was evaluated by adverse event (AE) analysis.
RESULTS AND LIMITATIONS: Thirty-four of the 36 implanted subjects completed the study. One subject withdrew voluntarily and one developed inflammation necessitating removal of the system. In the remaining subjects, 71% experienced clinical success at 6 months. Leaks/day, leak severity, and pad changes/day decreased significantly over time with 27.6% of urge incontinence subjects that became "dry." Voids/day, degree of urgency, volume/void, pads changed improved significantly. All quality of life aspects (concern, coping, sleep, and social) improved as well as symptom severity scores measured by the OAB-q. Adverse events included: implant site pain (13.9%), suspected infection (22.2%), and procedural wound complications (8.3%).
CONCLUSIONS: The BlueWind implantable tibial nerve stimulator is a safe, minimally invasive system that affords OAB patients significant improvements.
PATIENT SUMMARY: The performance and safety of the BlueWind RENOVA™ implantable tibial nerve neuromodulator for OAB was tested. Our preliminary results demonstrate that the system has a low risk safety profile and may be considered an effective treatment option for OAB management.
OBJECTIVE: Evaluation of the BlueWind implantable tibial nerve system performance and safety in refractory OAB.
DESIGN, SETTING, AND PARTICIPANTS INTERVENTION: A 6-month multi-center prospective intervention study.
OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Objective assessment was done by voiding diary parameters including voids/day, volume voided/day, urgency assessment, leaking episodes/day, pads used/day, leak severity, and clinical success defined as a ≥50% reduction in the number of leaks/day or number of voids/day or number of episodes with degree of urgency >2 or a return to <8 voids/day on a 3 Day diary. Subjective assessment was based on OAB-q including HRQL and symptom severity score. Safety was evaluated by adverse event (AE) analysis.
RESULTS AND LIMITATIONS: Thirty-four of the 36 implanted subjects completed the study. One subject withdrew voluntarily and one developed inflammation necessitating removal of the system. In the remaining subjects, 71% experienced clinical success at 6 months. Leaks/day, leak severity, and pad changes/day decreased significantly over time with 27.6% of urge incontinence subjects that became "dry." Voids/day, degree of urgency, volume/void, pads changed improved significantly. All quality of life aspects (concern, coping, sleep, and social) improved as well as symptom severity scores measured by the OAB-q. Adverse events included: implant site pain (13.9%), suspected infection (22.2%), and procedural wound complications (8.3%).
CONCLUSIONS: The BlueWind implantable tibial nerve stimulator is a safe, minimally invasive system that affords OAB patients significant improvements.
PATIENT SUMMARY: The performance and safety of the BlueWind RENOVA™ implantable tibial nerve neuromodulator for OAB was tested. Our preliminary results demonstrate that the system has a low risk safety profile and may be considered an effective treatment option for OAB management.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app