Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Ultrasound for the assessment of distal shunt malfunction in adults with internal ventricular shunts.

Shunts that are used for the treatment of hydrocephalus have a propensity towards malfunction, however, diagnosing a shunt malfunction can sometimes be a challenge. The purpose of this study was to investigate whether ultrasound technology can be safely and effectively used to assess for distal shunt malfunction. This was a prospective cohort study at a single institution. Eighteen adult patients that received a radionuclide shunt patency study also underwent an ultrasound shunt patency study. Ultrasound with Doppler technology was used to visualize flow through the shunt tubing following manual compression of the shunt reservoir. A peak flow speed was recorded and the results were compared to the results of the radionuclide shunt patency study. A Receiver Operating Characteristic (ROC) curve comparing the ultrasound to the radionuclide shunt patency study was generated, revealing an Area Under the Curve (AUC) of 0.95 (95% CI: 0.84-1.00). The ultrasound test performed maximally with a cutoff speed of ≤10cm/s as the criteria for malfunction, with a sensitivity of 100.00%, specificity of 90.91%, accuracy of 94.44%, positive likelihood ratio of 11.000 and negative likelihood ratio of 0.000 using the radionuclide study results as criteria for comparison. Overall, ultrasound has the potential to be a safe, quick, available and cost-effective screening test for patients with suspected distal shunt malfunction. The high sensitivity of the test makes it an attractive option for use as a screening method that could potentially reduce the number of cases requiring radionuclide shunt patency study.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app