Reproducibility of point-of-care ultrasonography for central vein diameter measurement: Separating image acquisition from interpretation.

PURPOSE: Central vein point-of-care ultrasonography must be reproducible to detect intravascular volume changes. We sought to determine which measurement step, image acquisition or interpretation, could be more compromising for reproducibility.

METHODS: Three investigators each acquired inferior vena cava (IVC) and internal jugular (IJV) vein ultrasonographic sequences (US) from a convenience sample of 21 hospitalized general medicine participants and then interpreted each US three separate times. We partitioned the random errors of acquisition and interpretation, attributing wider dispersions of each to larger reductions in reproducibility.

RESULTS: We analyzed 351 interpretations of 39 IVC and 432 interpretations of 48 IJV US. Reproducibility of the maximum (standard error of measurement 3.3 mm [95% confidence interval, CI 2.7-4.2 mm]) and minimum (4.8 mm [3.9-6.3 mm]) IVC diameter measurements were worse than that of the mediolateral (2.5 mm [2.0-3.2 mm]) and anteroposterior (2.5 mm [2.0-3.1 mm]) IJV diameters. The dispersions of random measurement errors were wider among acquisitions than interpretations.

CONCLUSIONS: Among our investigators, central vein diameter measurements obtained by point-of-care ultrasonography are not sufficiently reproducible to distinguish clinically meaningful intravascular volume changes from measurement errors. Reproducibility could be most effectively improved by reducing the random measurement errors of acquisition. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:488-496, 2017.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app