We have located links that may give you full text access.
Comparison of apical debris extrusion during root canal preparation using instrumentation techniques with two operating principles: An in vitro study.
Journal of Conservative Dentistry : JCD 2017 March
AIMS: The aim of this study was to quantify the debris extruded apically from teeth using rotary and reciprocation instrumentation systems.
SUBJECTS AND METHODS: Eighty extracted human mandibular premolars with single canals and similar lengths were instrumented using ProTaper Universal (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), WaveOne (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), and Reciproc (R40; VDW GmbH, Munich, Germany). Debris extruded during instrumentation was collected into preweighed Eppendorf tubes, which were then stored in an incubator at 70°C for 5 days. The final weight of the Eppendorf tubes with the extruded debris was calculated after obtaining the mean of three consecutive weights obtained for each tube.
STATISTICAL ANALYSIS USED: Statistical analysis was performed using SPSS version 16.0 software. The groups were compared using the Kruskal-Wallis test for all variables.
RESULTS: There was no statistically significant difference between the groups (P = 0.1114). However, the ProTaper Universal group produced more extrusion and ProTaper Next produced least debris extrusion among the instrument groups (P > 0.05).
CONCLUSIONS: All instrumentation techniques were associated with extruded debris.
SUBJECTS AND METHODS: Eighty extracted human mandibular premolars with single canals and similar lengths were instrumented using ProTaper Universal (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), WaveOne (40, 06; Dentsply Maillefer, Ballaigues, Switzerland), and Reciproc (R40; VDW GmbH, Munich, Germany). Debris extruded during instrumentation was collected into preweighed Eppendorf tubes, which were then stored in an incubator at 70°C for 5 days. The final weight of the Eppendorf tubes with the extruded debris was calculated after obtaining the mean of three consecutive weights obtained for each tube.
STATISTICAL ANALYSIS USED: Statistical analysis was performed using SPSS version 16.0 software. The groups were compared using the Kruskal-Wallis test for all variables.
RESULTS: There was no statistically significant difference between the groups (P = 0.1114). However, the ProTaper Universal group produced more extrusion and ProTaper Next produced least debris extrusion among the instrument groups (P > 0.05).
CONCLUSIONS: All instrumentation techniques were associated with extruded debris.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app