Add like
Add dislike
Add to saved papers

Enantioselective separation and determination of miconazole in rat plasma by chiral LC-MS/MS: application in a stereoselective pharmacokinetic study.

Miconazole has one chiral center, and consists of two enantiomers. In this study, a novel chiral liquid chromatography-tandem mass spectrometry method was developed for enantioselective separation and determination of miconazole in rat plasma. For the first time, the enantioselective pharmacokinetics of miconazole was investigated by the current method. Firstly, attempts were made to separate the enantiomers in reversed-phase mode with a mobile phase that was mass spectrometry compatible. Baseline separation was achieved on a Chiralpak IC column with a mobile phase composed of acetonitrile and aqueous ammonium hydrogen carbonate (5 mM; 80:20, v/v). Data were acquired in multiple reaction monitoring mode with positive electrospray ionization by triple-quadrupole mass spectrometry. Then, overall method validation regarding the linearity, accuracy, precision, extraction recovery, matrix effect, and stability of each enantiomer was performed, and acceptable results were obtained for all of these. Finally, the method developed was applied in an enantioselective pharmacokinetic study of miconazole enantiomers in rats after oral administration of racemic miconazole at doses of 5 and 10 mg/kg. The results demonstrated that (-)-(R)-miconazole had a higher concentration than (+)-(S)-miconazole in plasma, with a ratio of 1.3-1.7 for both doses. This is the first experimental evidence of enantioselective behavior of miconazole in vivo, and provides a reference for clinical practice and encourages further research into miconazole enantioselective metabolism and drug interactions. Graphical Abstract A stereoselective pharmacokinetic study of the miconazole enantiomers was investigated using a novel chiral liquid chromatography-tandem mass spectrometry method. Baseline separation was achieved on Chiralpak IC column, and Chiralcel OJ column was used to collect single enantiomer. A significant difference between the two enantiomers was observed in view of the plasma concentration.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app