We have located links that may give you full text access.
An UPLC Method for Determination of Geraniin in Rat Plasma and its Application to Pharmacokinetic Studies.
Current Pharmaceutical Analysis 2017 August
INTRODUCTION: Geraniin has many biological activities including anti-osteoporotic and anti-hyperglycemic efficacies.
MATERIALS AND METHODS: A rapid and simple method for the determination of geraniin in rat plasma using ultra performance liquid chromatography coupled to ultraviolet detector was developed. The plasma sample, spiked with epicatechin as an internal standard, was subjected to ethyl acetate extraction prior to analysis. Chromatographic separation was performed on the HSS T3 column and monitored at a wavelength of 280 nm. The limit of detection and lower limit of quantification was 0.07 μg/mL and 0.2 μg/mL in rat plasma, respectively.
CONCLUSION: Good linearity was obtained in the range of 0.2 - 200 μg/mL, and the correlation coefficient was better than 0.997. The intra-day and inter-day precisions decreased 9.8%. The accuracy of QC samples ranged from 84.4% to 87.1%. The extraction recovery ranged from 88.4% to 90.3% and the matrix effect ranged from 84.4% to 87.2%. The analyte was stable in rat plasma when stored at room temperature for 12 hours, 4°C for 24 hours and -20°C for 15 days. t1/2 and t1/2 for i.v. was 0.21 ± 0.10 and 7.20 ± 2.20 h, respectively. Plasma clearance (CL) was 0.03 ± 0.02 L/h/kg and apparent volume of distribution (Vz) was 0.05 + 0.01 L/kg. The developed method was successfully applied to the pharmacokinetic study of geraniin in rats.
MATERIALS AND METHODS: A rapid and simple method for the determination of geraniin in rat plasma using ultra performance liquid chromatography coupled to ultraviolet detector was developed. The plasma sample, spiked with epicatechin as an internal standard, was subjected to ethyl acetate extraction prior to analysis. Chromatographic separation was performed on the HSS T3 column and monitored at a wavelength of 280 nm. The limit of detection and lower limit of quantification was 0.07 μg/mL and 0.2 μg/mL in rat plasma, respectively.
CONCLUSION: Good linearity was obtained in the range of 0.2 - 200 μg/mL, and the correlation coefficient was better than 0.997. The intra-day and inter-day precisions decreased 9.8%. The accuracy of QC samples ranged from 84.4% to 87.1%. The extraction recovery ranged from 88.4% to 90.3% and the matrix effect ranged from 84.4% to 87.2%. The analyte was stable in rat plasma when stored at room temperature for 12 hours, 4°C for 24 hours and -20°C for 15 days. t1/2 and t1/2 for i.v. was 0.21 ± 0.10 and 7.20 ± 2.20 h, respectively. Plasma clearance (CL) was 0.03 ± 0.02 L/h/kg and apparent volume of distribution (Vz) was 0.05 + 0.01 L/kg. The developed method was successfully applied to the pharmacokinetic study of geraniin in rats.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app