Cardioscopically Guided Beating Heart Surgery: Paravalvular Leak Repair.
Annals of Thoracic Surgery 2017 September
PURPOSE: There remains a paucity of direct visualization techniques for beating-heart intracardiac procedures. To address this need, we evaluated a novel cardioscope in the context of aortic paravalvular leaks (PVLs) localization and closure.
DESCRIPTION: A porcine aortic PVL model was created using a custom-made bioprosthetic valve, and PVL presence was verified by epicardial echocardiography. Transapical delivery of occlusion devices guided solely by cardioscopy was attempted 13 times in a total of three pigs. Device retrieval after release was attempted six times. Echocardiography, morphologic evaluation, and delivery time were used to assess results.
EVALUATION: Cardioscopic imaging enabled localization of PVLs via visualization of regurgitant jet flow in a paravalvular channel at the base of the prosthetic aortic valve. Occluders were successfully placed in 11 of 13 attempts (84.6%), taking on average 3:03 ± 1:34 min. Devices were cardioscopically removed successfully in three of six attempts (50%), taking 3:41 ± 1:46 min. No damage to the ventricle or annulus was observed at necropsy.
CONCLUSIONS: Cardioscopy can facilitate intracardiac interventions by providing direct visualization of anatomic structures inside the blood-filled, beating-heart model.
DESCRIPTION: A porcine aortic PVL model was created using a custom-made bioprosthetic valve, and PVL presence was verified by epicardial echocardiography. Transapical delivery of occlusion devices guided solely by cardioscopy was attempted 13 times in a total of three pigs. Device retrieval after release was attempted six times. Echocardiography, morphologic evaluation, and delivery time were used to assess results.
EVALUATION: Cardioscopic imaging enabled localization of PVLs via visualization of regurgitant jet flow in a paravalvular channel at the base of the prosthetic aortic valve. Occluders were successfully placed in 11 of 13 attempts (84.6%), taking on average 3:03 ± 1:34 min. Devices were cardioscopically removed successfully in three of six attempts (50%), taking 3:41 ± 1:46 min. No damage to the ventricle or annulus was observed at necropsy.
CONCLUSIONS: Cardioscopy can facilitate intracardiac interventions by providing direct visualization of anatomic structures inside the blood-filled, beating-heart model.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app