We have located links that may give you full text access.
Feasibility of Cervical Epidural Anesthesia for Breast Cancer Surgery.
BACKGROUND: Effects of perioperative cervical level neuraxial blocks on the dissemination of cancer metastases have become a matter of substantial interest. However, experience with these catheters has been limited and data on feasibility and efficacy is sparse.
METHODS: Data from 39 patients scheduled to undergo breast cancer surgery while awake with a cervical epidural alone was retrospectively analyzed.
RESULTS: In 26 patients (66,7%, 95% CI 51,7-81,7) the cervical epidural catheter was sufficient for surgery. In one patient (2.6%, 95% CI 0-7.6) identification of the epidural space was not possible. Four patients (10.3%, 95% CI 0,7-19,9) had an insufficient sensory block. Seven patients (17.9%, 95% CI 5,7-30,1) had a partially insufficient sensory block. Rates of failed epidural blocks were not significantly different between different insertion levels. 21 patients (80.8%, 95% CI 65,4-96,1) developed hypotension and required an intravenous vasopressor. One patient developed nausea. In one patient the dura was accidentally punctured. No neurological damage was observed. No other major complications were observed.
DISCUSSION: Epidural punctures in the cervical region are feasible but do bear potential for major complications. Anesthesiologists should familiarize themselves with high epidural block techniques.
METHODS: Data from 39 patients scheduled to undergo breast cancer surgery while awake with a cervical epidural alone was retrospectively analyzed.
RESULTS: In 26 patients (66,7%, 95% CI 51,7-81,7) the cervical epidural catheter was sufficient for surgery. In one patient (2.6%, 95% CI 0-7.6) identification of the epidural space was not possible. Four patients (10.3%, 95% CI 0,7-19,9) had an insufficient sensory block. Seven patients (17.9%, 95% CI 5,7-30,1) had a partially insufficient sensory block. Rates of failed epidural blocks were not significantly different between different insertion levels. 21 patients (80.8%, 95% CI 65,4-96,1) developed hypotension and required an intravenous vasopressor. One patient developed nausea. In one patient the dura was accidentally punctured. No neurological damage was observed. No other major complications were observed.
DISCUSSION: Epidural punctures in the cervical region are feasible but do bear potential for major complications. Anesthesiologists should familiarize themselves with high epidural block techniques.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app