Liquid chromatography - quadrupole Orbitrap mass spectrometry method for selected pharmaceuticals in water samples.
Journal of Chromatography. A 2017 September 16
This study developed an analytical approach for sub-ppb level detection and confirmation of 13 pharmaceuticals and personal care products (PPCPs) in water samples using ultra high pressure liquid chromatography hyphenated with a quadrupole Orbitrap mass spectrometer (UHPLC- Q-Orbitrap-MS). Sample preparation was performed by using solid phase extraction (SPE) employing hydrophilic-lipophilic balance cartridges, with elution of sorbed analytes using methanol. Acceptable automatic gain control (AGC) target and maximum injection time (IT) were 1×106 and 200ms, respectively, resulting in a mass accuracy <2ppm. High response signals with sufficient data points per peaks (20-30) were obtained whilst maintaining high resolution of approximately 70,000 full width at half maximum. Extracted ion chromatograms provided quantitative analysis with linearity (R2 ) ranging from 0.9875 to 0.9993 and method detection limits ranging from 0.01-0.61ngmL-1 . Compounds were further analysed by MS/MS analysis, with the MS operated in parallel reaction monitoring (PRM) mode under precursor ion analysis intervals and collision energies chosen for the different PPCPs. The developed method was applied to analyse water samples obtained from sources in Victoria, Australia.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app