We have located links that may give you full text access.
The impact of global left ventricular afterload on left ventricular reverse remodeling after aortic valve replacement.
Journal of Cardiac Surgery 2017 September
BACKGROUND: Conventional indices such as prosthetic valve effective orifice area (EOA) or transvalvular pressure gradients (TPG) may be unreliable in predicting left ventricular (LV) reverse remodeling after aortic valve replacement (AVR). We hypothesized that the global LV afterload, including valvular and arterial impedance, could influence LV reverse remodeling after AVR.
METHODS: Twenty-three consecutive aortic-stenosis patients (mean age, 76 ± 6.4 years) underwent isolated AVR using contemporary externally wrapped pericardial valves (19 mm, 10 patients; 21 mm 11; 23 mm, 2). Valvuloarterial impedance (Zva), a marker of global LV afterload, was measured on serial echocardiography in addition to indexed EOA, energy loss index (ELI), mean TPG, and stroke work loss. LV mass regression was used as a parameter of LV reverse remodeling.
RESULTS: The Zva significantly decreased after AVR (5.05 ± 1.7 mmHg/mL/m2 , pre-operatively; 3.12 ± 1.0, postoperatively; 3.13 ± 0.89, at last follow-up) in parallel with increased indexed EOA (0.46 ± 0.13 cm2 /m2 ; 1.13 ± 0.24; 0.96 ± 0.19), ELI (0.55 ± 0.21 cm2 /m2 ; 1.74 ± 0.52; 1.47 ± 0.42), and decreased mean TPG (50.2 ± 19.6 mmHg; 11.1 ± 5.4; 14.7 ± 5.8). The stroke work loss also decreased (26.3 ± 8.5 %; 8.65 ± 4.0; 9.36 ± 3.4). The Zva at last follow-up was significantly correlated with LV mass regression (correlation coefficient, r = - 0.48; P = 0.002), and was a significant predictor of LV reverse remodeling on multiple regression analysis (adjusted odds ratio, -0.43; 95% confidence interval, -31.3 to -0.67, P = 0.042), while indexed EOA, ELI, mean TPG, or systemic arterial compliance were not.
CONCLUSIONS: The postoperative Zva was significantly associated with LV mass regression after AVR. Maintaining low global LV afterload following AVR may enhance LV reverse remodeling.
METHODS: Twenty-three consecutive aortic-stenosis patients (mean age, 76 ± 6.4 years) underwent isolated AVR using contemporary externally wrapped pericardial valves (19 mm, 10 patients; 21 mm 11; 23 mm, 2). Valvuloarterial impedance (Zva), a marker of global LV afterload, was measured on serial echocardiography in addition to indexed EOA, energy loss index (ELI), mean TPG, and stroke work loss. LV mass regression was used as a parameter of LV reverse remodeling.
RESULTS: The Zva significantly decreased after AVR (5.05 ± 1.7 mmHg/mL/m2 , pre-operatively; 3.12 ± 1.0, postoperatively; 3.13 ± 0.89, at last follow-up) in parallel with increased indexed EOA (0.46 ± 0.13 cm2 /m2 ; 1.13 ± 0.24; 0.96 ± 0.19), ELI (0.55 ± 0.21 cm2 /m2 ; 1.74 ± 0.52; 1.47 ± 0.42), and decreased mean TPG (50.2 ± 19.6 mmHg; 11.1 ± 5.4; 14.7 ± 5.8). The stroke work loss also decreased (26.3 ± 8.5 %; 8.65 ± 4.0; 9.36 ± 3.4). The Zva at last follow-up was significantly correlated with LV mass regression (correlation coefficient, r = - 0.48; P = 0.002), and was a significant predictor of LV reverse remodeling on multiple regression analysis (adjusted odds ratio, -0.43; 95% confidence interval, -31.3 to -0.67, P = 0.042), while indexed EOA, ELI, mean TPG, or systemic arterial compliance were not.
CONCLUSIONS: The postoperative Zva was significantly associated with LV mass regression after AVR. Maintaining low global LV afterload following AVR may enhance LV reverse remodeling.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app