The impact of a hospital electronic prescribing and medication administration system on medication administration safety: an observational study.

BACKGROUND: The aim of the study was to explore the impact of the implementation of an electronic prescribing and medication administration system (ePA) on the safety of medication administration in an inpatient hospital setting. Objectives were to compare the prevalence and types of: 1) medication administration errors, and 2) documentation discrepancies, between a paper and an ePA system. Additionally, we wanted to describe any observed changes to medication administration practices.

METHODS: The study was based on an elderly medicine ward in an English hospital. From December 2014 to June 2015, nurses' medication administration rounds were observed every 5 days before and after ePA implementation using an interrupted time-series approach. Medication administration error and documentation discrepancy rates pre- versus post-ePA were analysed descriptively and chi-squared tests used to test for any difference; segmented regression analysis was used to determine changes in longitudinal trend.

RESULTS: Observations were made at 15 pre- and 15 post-ePA implementation time-points. Pre-ePA on paper, there were 18 medication administration errors in 428 opportunities for error (4.2%; 95% confidence interval 2.3-6.1%), and with ePA there were 18 in 528 (3.4%; 95% confidence interval 1.9-5.0%; p = 0.64). Regarding documentation, pre-ePA on paper there were 5 discrepancies in 460 observed documentations (1.1%; 95% confidence interval 0.1-2.0%); with ePA there were 18 in 557 (3.2%; 95% confidence interval 1.8-4.7%; p = 0.04). The most common electronic documentation discrepancy was documentation that a dose had been administered when it had not. Segmented regression analysis was unable to detect any significant longitudinal changes. Changes to working practices post-ePA were observed, such as nurses demonstrating less-consistent self-checking when preparing and administering medications.

CONCLUSIONS: Findings suggest no change in medication error rate, although ePA encourages certain types of errors and mitigates others. There was a statistically significant increase in documentation discrepancies which is likely to be due to adoption of new working practices with ePA.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app