Kiwi omnicup handheld versus Mityvac M-style conventional vacuum system: a retrospective observational study.
Journal of Maternal-fetal & Neonatal Medicine 2018 December
INTRODUCTION: To improve the choice of vacuum-assisted delivery (VAD) system, we compared the outcomes of Kiwi handheld system and Mityvac M-style conventional system (both use disposable plastic cups).
MATERIALS AND METHODS: Retrospective observational study with data collection from electronic medical records. The study was conducted at a tertiary medical center, with approximately 7000 deliveries annually. Categorical and continuous variables were analyzed using chi-square test and t-test, respectively. p value < .05 was considered significant. The main outcomes assessed were the overall failure rate of each system, failure rates for occipito-anterior (OA) versus occipito-transverse/occipito-anterior (OT/OP) positions, +1 versus +2 fetal stations, and early maternal/neonatal outcomes.
RESULTS: During a 10-month period, there were 507 (8.4%) attempted VADs, 36 failed (7.1%), and eight (1.5%) converted to cesarean section. Of these, 364 were Kiwi-assisted and 143 Mityvac-assisted. Background characteristics were similar. The handheld system had more failures overall (9.6 versus 0.7%), at OA (7.6 versus 0.9%), and non-OA positions (17.3% versus none), at +1 (13.25 versus 0.96%) and at +2/3 stations (6.1% versus none), than the conventional system did, respectively. There was a higher rate of early post-partum hemorrhage (15.3 versus 7.4%) in the conventional group. Both systems had similar rates of third/fourth degree perineal tears, shoulder dystocia and adverse neonatal outcomes.
CONCLUSIONS: Our results suggest more failures with Kiwi compared to Mityvac, overall and at any fetal position/station, without a significant difference in adverse outcome profile.
MATERIALS AND METHODS: Retrospective observational study with data collection from electronic medical records. The study was conducted at a tertiary medical center, with approximately 7000 deliveries annually. Categorical and continuous variables were analyzed using chi-square test and t-test, respectively. p value < .05 was considered significant. The main outcomes assessed were the overall failure rate of each system, failure rates for occipito-anterior (OA) versus occipito-transverse/occipito-anterior (OT/OP) positions, +1 versus +2 fetal stations, and early maternal/neonatal outcomes.
RESULTS: During a 10-month period, there were 507 (8.4%) attempted VADs, 36 failed (7.1%), and eight (1.5%) converted to cesarean section. Of these, 364 were Kiwi-assisted and 143 Mityvac-assisted. Background characteristics were similar. The handheld system had more failures overall (9.6 versus 0.7%), at OA (7.6 versus 0.9%), and non-OA positions (17.3% versus none), at +1 (13.25 versus 0.96%) and at +2/3 stations (6.1% versus none), than the conventional system did, respectively. There was a higher rate of early post-partum hemorrhage (15.3 versus 7.4%) in the conventional group. Both systems had similar rates of third/fourth degree perineal tears, shoulder dystocia and adverse neonatal outcomes.
CONCLUSIONS: Our results suggest more failures with Kiwi compared to Mityvac, overall and at any fetal position/station, without a significant difference in adverse outcome profile.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app