Evaluation of an automated quantitative latex immunoturbidimetric non-treponemal assay for diagnosis and follow-up of syphilis: a prospective cohort study.

PURPOSE: We evaluated the Sekure rapid plasma reagin (RPR-S) (Sekisui Diagnostics) automated quantitative latex immunoturbidimetric assay performed on the SK500 clinical chemistry system for clinical appropriateness.

METHODOLOGY: Syphilis-infected individuals and controls were recruited into a prospective cohort study conducted at a sexually transmitted infection clinic in Antwerp, Belgium. Sera collected at diagnosis (baseline) and at 3, 6, 9 and 12 months post-treatment were tested with RPR-S and Macro-Vue RPR card (RPR-C) (Becton Dickinson) assays; RPR-C was considered the reference test. IgG/IgM enzyme immunoassay and Treponema pallidum polA serum PCR results were consulted by discordancy at baseline. Categorical analyses were performed and correlations were assessed with (non)-linear regression. Post-treatment longitudinal serological evolution was evaluated.

RESULTS: A total of 463 samples from 120 new syphilis cases from a variety of clinical stages and 30 syphilis-negative controls were tested. Initially, there was a weak correlation between quantitative RPR-C/S (r=0.15). In 70 samples there was a strong suspicion of hook effect. Of these, 57/70 sera were retested with an extra dilution step, resulting in an average 12-fold increase in quantitative RPR-S results. After the extra dilution, the overall qualitative RPR-C/S agreement was 78.89 %, (κ-coefficient: 0.484). Of the 92 discordant samples, 9 were from the baseline visit (RPR-C titre: 1-8), which could have led to possible missed diagnoses using the RPR-S.

CONCLUSIONS: The sensitivity and accuracy of the RPR-S test requires improvement before it can be used to diagnose syphilis and evaluate treatment efficacy in clinical practice.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app