Intrathecal Migration of an Epidural Catheter While Using a Programmed Intermittent Epidural Bolus Technique for Labor Analgesia Maintenance: A Case Report.

A & A Case Reports 2017 December 16
We describe a case of intrathecal migration of a wire-reinforced epidural catheter in a parturient who received epidural labor analgesia. Epidural analgesia was initiated with a combined-spinal epidural technique and maintained by programmed intermittent epidural boluses. Epidural catheter aspiration after insertion was negative for cerebrospinal fluid. The patient's response to the first four doses of local anesthetic was consistent with epidural drug delivery. After the fifth dose, she developed a complete lower extremity motor block, hypotension, and high sensory blockade. Catheter aspiration was then positive for cerebrospinal fluid. After symptom resolution, labor pain was successfully managed with this inadvertent intrathecal catheter.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app