JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Association Between Concentrations of Hemoglobin Determined by Fecal Immunochemical Tests and Long-term Development of Advanced Colorectal Neoplasia.

Gastroenterology 2017 November
BACKGROUND & AIMS: Colorectal cancer (CRC) screening using quantitative fecal immunochemical tests (FITs) is rapidly gaining ground worldwide. FITs are invariably used in a dichotomous manner using pre-specified cut-off values. To optimize FIT-based screening programs, we investigated the association between fecal hemoglobin (f Hb) concentrations below the FIT cut-off value and later development of colorectal advanced neoplasia (AN).

METHODS: We analyzed data collected from a population-based study of 9561 average-risk subjects (50-74 years old) in the Netherlands who were offered 4 rounds of FIT screening for CRC from November 2006 through December 2014. We analyzed data from 7663 participants screened at least once and found to have a negative FIT result at baseline (below the cut-off value of 10 μg Hb/ g feces). Participants were followed for a median of 4.7 years (interquartile range, 2.0-6.1 years); CRCs diagnosed outside the screening program were identified from the Dutch Comprehensive Cancer Centre database. Hazard ratios for AN were determined using Cox proportional hazard regression analyses. Logistic regression techniques were used to calculate risks of AN after consecutive fHb concentrations below the cut-off value.

RESULTS: After 8 years of follow-up, participants with baseline concentrations of 8-10 μg fHb/g had a higher cumulative incidence of AN (33%) than participants with 0 μg fHb/g (5%) (P < .001). Multi-variate hazard ratios increased from 1.2 for subjects with concentrations of 0-2 μg fHb/g to 8.2 for subjects with concentrations of 8-10 μg fHb/g (P < .001). Participants with 2 consecutive fHb concentrations of 8 μg Hb/g had a 14-fold increase in risk of AN compared with participants with 2 consecutive fHb concentrations of 0 μg Hb/g (P < .001).

CONCLUSIONS: In a population-based study of average-risk individuals with a FIT result below the cut-off value, we associated baseline concentrations of 8-10 μg fHb/g with an increased risk of AN compared with baseline concentrations of 0 μg fHb/g. Baseline and consecutive fHb concentrations are independent predictors for incident AN. This information might be used in designing personalized strategies for population-based CRC screening and reduce unnecessary repeat tests. Trialregister.nl no: first round, NTR1096; second round and additional invitees, NTR1512.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app