Interphalangeal arthrodesis using an intramedullary nitinol implant: a prospective study.
Joint Diseases & related Surgery 2017 August
OBJECTIVES: This study aims to evaluate the nitinol (X-Fuse®) implant in arthrodesis of the distal interphalangeal and the thumb joints with respect to bone fusion and clinical efficiency.
PATIENTS AND METHODS: This prospective study included 24 consecutive patients (7 males, 17 females; mean age 56.8 years; range 27 to 79 years) with nitinol (X-Fuse®) implants in their 41 joints. All patients were followed-up clinically and radiographically with respect to fusion, complications and outcome at a minimum of 14 months postoperatively (mean 28±6 months). X-rays, Disabilities of the Arm, Shoulder and Hand, and visual analog scale scores were recorded preoperatively and at postoperative fifth week, third month, first year, and subsequent visits.
RESULTS: The Disabilities of the Arm, Shoulder and Hand score improved significantly from preoperative 37.7 points to postoperative 14.5 points at first year. The visual analog scale score improved significantly from preoperative 5.5 to postoperative 0.85 points at first year. Failure to fuse only occurred in two joints (5%), resulting in fusion after reoperation. No other severe complications such as deep infection, intraoperative fracture, wound healing problems or regional dystrophy were observed.
CONCLUSION: The X-Fuse® implant may be a reliable alternative method for finger joint arthrodesis.
PATIENTS AND METHODS: This prospective study included 24 consecutive patients (7 males, 17 females; mean age 56.8 years; range 27 to 79 years) with nitinol (X-Fuse®) implants in their 41 joints. All patients were followed-up clinically and radiographically with respect to fusion, complications and outcome at a minimum of 14 months postoperatively (mean 28±6 months). X-rays, Disabilities of the Arm, Shoulder and Hand, and visual analog scale scores were recorded preoperatively and at postoperative fifth week, third month, first year, and subsequent visits.
RESULTS: The Disabilities of the Arm, Shoulder and Hand score improved significantly from preoperative 37.7 points to postoperative 14.5 points at first year. The visual analog scale score improved significantly from preoperative 5.5 to postoperative 0.85 points at first year. Failure to fuse only occurred in two joints (5%), resulting in fusion after reoperation. No other severe complications such as deep infection, intraoperative fracture, wound healing problems or regional dystrophy were observed.
CONCLUSION: The X-Fuse® implant may be a reliable alternative method for finger joint arthrodesis.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university