We have located links that may give you full text access.
Quick Sequential Organ Failure Assessment and Systemic Inflammatory Response Syndrome Criteria as Predictors of Critical Care Intervention Among Patients With Suspected Infection.
Critical Care Medicine 2017 November
OBJECTIVES: The Sepsis III clinical criteria for the diagnosis of sepsis rely on scores derived to predict inhospital mortality. In this study, we introduce the novel outcome of "received critical care intervention" and investigate the related predictive performance of both the quick Sequential Organ Failure Assessment and the Systemic Inflammatory Response Syndrome criteria.
DESIGN: This was a single-center, retrospective analysis of electronic health records.
SETTING: Tertiary care hospital in the United States.
PATIENTS: Patients with suspected infection who presented to the emergency department and were admitted to the hospital between January 2010 and December 2014.
INTERVENTIONS: Systemic Inflammatory Response Syndrome and quick Sequential Organ Failure Assessment scores were calculated, and their relationships to the receipt of critical care intervention and inhospital mortality were determined.
MEASUREMENT AND MAIN RESULTS: A total of 24,164 patients were included of whom 6,693 (27.7%) were admitted to an ICU within 48 hours; 4,453 (66.5%) patients admitted to the ICU received a critical care intervention. Among those with quick Sequential Organ Failure Assessment less than 2, 13.4% received a critical care intervention and 3.5% died compared with 48.2% and 13.4%, respectively, for quick Sequential Organ Failure Assessment greater than or equal to 2. The area under the receiver operating characteristic was similar whether quick Sequential Organ Failure Assessment was used to predict receipt of critical care intervention or inhospital mortality (0.74 [95% CI, 0.73-0.74] vs 0.71 [0.69-0.72]). The area under the receiver operating characteristic of Systemic Inflammatory Response Syndrome for critical care intervention (0.69) and mortality (0.66) was lower than that for quick Sequential Organ Failure Assessment (p < 0.001 for both outcomes). The sensitivity of quick Sequential Organ Failure Assessment for predicting critical care intervention was 38%.
CONCLUSIONS: Emergency department patients with suspected infection and low quick Sequential Organ Failure Assessment scores frequently receive critical care interventions. The misclassification of these patients as "low risk," in combination with the low sensitivity of quick Sequential Organ Failure Assessment greater than or equal to 2, may diminish the clinical utility of the quick Sequential Organ Failure Assessment score for patients with suspected infection in the emergency department.
DESIGN: This was a single-center, retrospective analysis of electronic health records.
SETTING: Tertiary care hospital in the United States.
PATIENTS: Patients with suspected infection who presented to the emergency department and were admitted to the hospital between January 2010 and December 2014.
INTERVENTIONS: Systemic Inflammatory Response Syndrome and quick Sequential Organ Failure Assessment scores were calculated, and their relationships to the receipt of critical care intervention and inhospital mortality were determined.
MEASUREMENT AND MAIN RESULTS: A total of 24,164 patients were included of whom 6,693 (27.7%) were admitted to an ICU within 48 hours; 4,453 (66.5%) patients admitted to the ICU received a critical care intervention. Among those with quick Sequential Organ Failure Assessment less than 2, 13.4% received a critical care intervention and 3.5% died compared with 48.2% and 13.4%, respectively, for quick Sequential Organ Failure Assessment greater than or equal to 2. The area under the receiver operating characteristic was similar whether quick Sequential Organ Failure Assessment was used to predict receipt of critical care intervention or inhospital mortality (0.74 [95% CI, 0.73-0.74] vs 0.71 [0.69-0.72]). The area under the receiver operating characteristic of Systemic Inflammatory Response Syndrome for critical care intervention (0.69) and mortality (0.66) was lower than that for quick Sequential Organ Failure Assessment (p < 0.001 for both outcomes). The sensitivity of quick Sequential Organ Failure Assessment for predicting critical care intervention was 38%.
CONCLUSIONS: Emergency department patients with suspected infection and low quick Sequential Organ Failure Assessment scores frequently receive critical care interventions. The misclassification of these patients as "low risk," in combination with the low sensitivity of quick Sequential Organ Failure Assessment greater than or equal to 2, may diminish the clinical utility of the quick Sequential Organ Failure Assessment score for patients with suspected infection in the emergency department.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app